I
I
I
I
I
I
I
Applications
Mechanical engineering, plant control
Approvals
V
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Limiting making capacity, max 20 ms
Contact material
Minimum contact load
Mechanical endurance
Rated frequency of operation with / without load
Contact ratings
Type
MT321
MT321
MT321
MT3..
MT2..
MT2..
Coil data
Rated coil voltage range DC coil
Coil power DC coil
Operative range
Coil versions, DC-coil
Coil code
All figures are given for coil without preenergization, at ambient temperature +23°C
*) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10
Datasheet
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
STD
006
012
024
048
060
110
220
2 / 3 pole 10 A, 2 CO or 3 CO contacts
DC and AC coils
Mechanical indicator as standard
Electrical indicator
New test system with front operated finger protected
push-to-test button and integral locking test tab
White write on panel
RoHS compliant (Directive 2002/95/EC)
as per product date code 0415
REG.-Nr. 6182,
Load
10 A, 250 VAC, CO contact, cosϕ=1, 360/h, df 50%, 35°C
I
I
2 A, 125 V, L/R 30 ms, 3 NO contacts in series, 1800/h, DF 10%
0.7 A, 125 V, L/R 20 ms, 2 NO contacts in series, 1800/h, DF 10%
1 A, 125 V, L/R 20 ms, 2 NO contacts in series, 1800/h, DF 10%
on
on
AC coil
50 A, I
30 A, I
PD*)
0C4
0G0
2C0
0A6
0B2
0E8
1B0
Rev. EK1
off
off
Z
5 A, 3x440 VAC, NO, cosϕ=0.3, AC15, normal cond.
3 A, 3x440 VAC, NC, cosϕ=0.3, AC15, normal cond.
voltage
AC coil
Rated
VDC
110
220
12
24
48
60
6
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
E214025
General Purpose Relays
Multimode Relay MT
Operate
165.0
voltage
18.0
36.0
45.0
82.5
VDC
4.5
9.0
single cont.
AgNi90/10
12V/10mA
2500 VA
10 A
20 A
Release
voltage
11.5
22.0
VDC
0.6
1.2
2.4
4.8
6.0
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
micro disconnection
20x10
2 CO or 3 CO
240/400 VAC
20/100 min
6...220 VDC
6...230 VAC
single cont.
gold plated
20mV/1mA
AgNi90/10
10000+12%
40000+15%
2500 VA
resistance
2000+10%
2850+10%
2.3 VA
1.2 W
10 A
20 A
110+10%
475+ + 10%
6
32+10%
Ohm
1
Coil
cycles
-1
gold plated
20mV/1mA
AgNi90/10
Cycles
2.2x10
6x10
6x10
1x10
2x10
4x10
bifurcated
500 VA
Rated coil
4 A
8 A
power
3
3
5
5
4
1.1
1.3
1.2
1.3
1.2
1.2
1.2
W
5
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
F0161-A
1