CF2-12V Panasonic Electric Works, CF2-12V Datasheet - Page 3

RELAY AUTO TWIN POWER 12VDC PCB

CF2-12V

Manufacturer Part Number
CF2-12V
Description
RELAY AUTO TWIN POWER 12VDC PCB
Manufacturer
Panasonic Electric Works
Series
CFr
Datasheet

Specifications of CF2-12V

Relay Type
Automotive
Contact Form
SPDT (1 Form C) Dual
Contact Rating (current)
10A
Switching Voltage
12VDC
Coil Type
Standard
Coil Current
53mA
Coil Voltage
12VDC
Turn On Voltage (max)
7.2 VDC
Turn Off Voltage (min)
1 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C) Dual
Contact Rating @ Voltage
10A @ 12VDC
Control On Voltage (max)
7.2 VDC
Control Off Voltage (min)
1 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2182
CF2-12V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CF2-12V
Manufacturer:
MAXIM
Quantity:
101
Company:
Part Number:
CF2-12V
Quantity:
2 817
CF
6-(1). Electrical life test (Motor free)
Sample: CF2-12V, 3pcs.
Load: Inrush current: 30A, Steady current: 7A,
Power window motor actual load (free condition)
Switching frequency: (ON:OFF = 1s:5s)
Ambient temperature: Room temperature
Circuit
Load current waveform
Inrush current: 27A, Steady current: 8.4A
Brake current: 15A
6-(2). Electrical life test (Motor lock)
Sample: CF2-12V, 3pcs.
Load: 20A 14V DC,
Power window motor actual load (lock condition)
Switching frequency: (ON:OFF = 1s:5s)
Ambient temperature: Room temperature
Circuit
Load current waveform
For Cautions for Use, see Relay Technical Information.
Relay 1
Relay 2
Relay 1
Relay 2
3s
3s
6s (1 cycle)
6s (1 cycle)
1s
1s
M
Power window
motor (free)
1s
1s
Power window
motor (lock)
10A
M
5A
200ms
200ms
Resistive
load
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
10
10
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
0
0
5
Drop-out voltage
No. of operations,
No. of operations,
Drop-out voltage
Pick-up voltage
Pick-up voltage
10
15
10
10
4
4
20
5
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
X
X
X
X
Order Discontinued as of October 31, 2009
Change of contact resistance
Change of contact resistance
50
40
30
20
10
50
40
30
20
10
0
0
0
0
No. of operations,
No. of operations,
10
2.5
10
10
4
4
20
5
Max.
Min.
Max.
Min.
X
X

Related parts for CF2-12V