SF4D-DC24V Panasonic Electric Works, SF4D-DC24V Datasheet

RELAY SAFETY 6A 24VDC PCMNT 8PST

SF4D-DC24V

Manufacturer Part Number
SF4D-DC24V
Description
RELAY SAFETY 6A 24VDC PCMNT 8PST
Manufacturer
Panasonic Electric Works
Series
SFr
Type
Safety Relayr
Datasheets

Specifications of SF4D-DC24V

Relay Type
Safety
Contact Form
8PST (4 Form A, 4 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
14.4 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
8PST (4 Form A, 4 Form B)
Contact Rating @ Voltage
6A @ 250VAC
Control On Voltage (max)
14.4 VDC
Control Off Voltage (min)
3.6 VDC
Brand/series
SF Series
Current, Rating
6 A
Function
Safety
Material, Contact
Gold-Flashed Silver Alloy
Number Of Pins
18
Resistance, Coil
1.152 Ohms
Standards
cULus, TUV, CSA
Temperature, Operating
-40 to +70 °C
Termination
Solder
Voltage, Breakdown
2500 V (RMS) (Between Contacts and Coil)
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Weight
1.66 Oz. (Approx.)
Relay Construction
Non-Latching
Contact Arrangement
4PST-NO/4PST-NC
Coil Voltage Dc
24V
Voltage Rating (vdc)
30V
Voltage Rating (vac)
440V
Dropout Volt (min)
3.6VDCV
Coil Resistance
1.152kohm
Pick-up Voltage (max)
18VDC
Maximum Power Rating
180W/1.5KVA
Operate Time
30ms
Contact Current Rating
6A
Contact Material
Silver Tin Oxide/Gold Flash
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
16.5mm
Product Depth (mm)
33mm
Product Length (mm)
53.3mm
Operating Temp Range
-40C to 70C
Pin Count
18
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1441

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SF4D-DC24V
Quantity:
29
ds_61407_en_sf4d: 011010D
SPECIFICATIONS
Contact
Coil
Remarks
*1 According to EN 60947-5-1: 1997, table 4 AC15 / DC13
*2 Contact interruption <10s
*3 Breathing hole open
ORDERING INFORMATION
Ex. SF4D
Contact configuration (a = normally open / NO,
b = normally closed / NC)
Contact material
Contact resistance (initial at 6V DC, 1A)
Making and breaking capacities (breathing
hole open)
Max. switching voltage
Min. switching voltage / min. switching current
Pick-up / drop-out / bounce time
(approx. values at U
Mechanical life
Operate / release voltage (% of U
20°C)
Pick-up/nominal power consumption at 20°C
Tolerance 0.3mm
Weight approx. 47g
Note: Standard packing; Carton: 20 pcs. Case 200 pcs.
Coil voltage (DC)
*1
5, 9, 12, 18, 21
24, 36, 48, 60
DC12 V
53.3
nominal
)
nominal
at
length: 3.0
33
AgSnO
POLARIZED, MONOSTABLE
6A 250V / 3A 24V
18.5 / 7.5 / 3ms
16.5
280 / 500mW
10V / 10mA
75% / 15%
SAFETY RELAY WITH
2
10
DOUBLE CONTACTS
, with Au flash
4a4b
30m
400V
FORCIBLY GUIDED
7
ops
Features
• Relay complies with EN 50205, Type B
• Overvoltage category as per IEC 60664-1 III / 4kV
• Rated voltage
as per IEC 60664-1
basic insulation
Coil-contact
Contact-contact
Characteristics
Important: Relay characteristics may be influenced by:
• strong external magnetic fields
• magnetic conductive materials near the relay
• narrow top-to-top mounting (printed surface to printed surface)
Note:
Suitable for most common washing methods except ultrasonic cleaning.
Max. switching frequency (without load)
Permissible ambient temperature at nominal
power consumption
Upper temperature limit
Test voltage:
open contact / contact-contact / contact-coil
Insulation resistance at 500V DC (initial)
Shock resistance (11ms) NO/NC
Vibration resistance 10 – 200 Hz (10 – 55 Hz,
amplitude 2 mm)
Degree of protection
Unit weight
forcibly linked
pair only
all other
contacts
*2
inside
400V
250V
400V
2
Polution degree
outside
*2
400V
250V
400V
RELAY
2
SF4D
inside
250V
250V
400V
3
-40°C to +70°C
2500 / 2500 /
IP67 / IP30
2500V
105°C
10Hz
10
30G
10G
47g
SF4D
9
rms
*3
1

Related parts for SF4D-DC24V

SF4D-DC24V Summary of contents

Page 1

... Pick-up/nominal power consumption at 20°C Remarks *1 According to EN 60947-5-1: 1997, table 4 AC15 / DC13 *2 Contact interruption <10s *3 Breathing hole open ORDERING INFORMATION Ex. SF4D DC12 V Coil voltage (DC 12, 18, 21 24, 36, 48, 60 Note: Standard packing; Carton: 20 pcs. Case 200 pcs. ds_61407_en_sf4d: 011010D ...

Page 2

... SF4D COIL DATA Coil nominal voltage Part number V DC SF4D-DC5V 5 SF4D-DC9V 9 SF4D-DC12V 12 SF4D-DC18V 18 SF4D-DC21V 21 SF4D-DC24V 24 SF4D-DC36V 36 SF4D-DC48V 48 SF4D-DC60V 60 ELECTRICAL LIFE Voltage Current 230V AC 8A 250V AC 6A 230V AC 6A 230V 24V DC 8A 24V DC 3A 24V 60947-5-1: 1997; table C.1 *2 Breathing hole closed *3 Breathing hole open *4 Ambient temperature +70° ...

Page 3

... APPLICATION NOTES Actuator Nipple If required a breathing hole can be made in the cover by removing the nipple. However be aware that the degree of protection will reduce from IP67 to IP30! ds_61407_en_sf4d: 011010D 100 110 your local Panasonic Electric Works representative. External dimensions 16±0.5 .630±.020 ...

Page 4

... If an inner contact should weld, then the movement of the rotating armature is blocked via the actuator. Open contacts of all four contact pairs remain open. This arrangement corresponds to a conventional forcibly guided contact operation. Actuator Outer contact Inner contact Rotating armature For Cautions for Use, see 4 Relay Technical Information. ds_61407_en_sf4d: 011010D ...

Related keywords