CR7310-EL-120-.01.1-X-CD-ELR-I CR Magnetics Inc, CR7310-EL-120-.01.1-X-CD-ELR-I Datasheet - Page 2

RELAY GROUND FAULT SENS 120V

CR7310-EL-120-.01.1-X-CD-ELR-I

Manufacturer Part Number
CR7310-EL-120-.01.1-X-CD-ELR-I
Description
RELAY GROUND FAULT SENS 120V
Manufacturer
CR Magnetics Inc
Series
CR7310r

Specifications of CR7310-EL-120-.01.1-X-CD-ELR-I

Relay Type
Current Sense
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 240VAC
Coil Type
Standard
Coil Voltage
120VAC
Control On Voltage (max)
Adjustable
Control Off Voltage (min)
Adjustable
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
582-1082
Shown with Internal Transformer Option (-l)
SUPPLY POWER TERMINALS
1/4" MALE QUICK CONNECT
TYPICAL 2 PLACES
Another HUNTINGTON ELECTRIC Company
CRGFS -
2 1/8 (54)
MAX.
7/8 (22.2)
TRIP STATUS
EH - Energized on High, trips
when sense current is above trip
point and returns to non-trip
status when sense current is
below the trip point.
EL - Energized on Low, trips
when sense current is below trip
point and returns to non-trip
status when sense current is
above the trip point.
LH - Latch on High, trips when
sense current is above trip point
and remains tripped until
supply power is removed.
LL - Latch on Low, trips when
sense current is below trip point
and remains tripped until supply
power is removed.
3 1/2
(88.9)
.50 (12.7) DIA.
CR7310 -
9/32 (7.14)
2 15/16
(74.6)
OUTLINE DRAWING
100 - 1.65 dia. Window
200 - 1.83 dia. Window
NC NO COM
1 15/16 (49.2)
1/4" MALE QUICK CONNECT
OUTPUT RELAY TERMINALS
TYPICAL 3 PLACES
2 1/2 (63.5)
CR Magnetics, Inc. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
EXTERNAL CURRENT SENSING TRANSFORMER
SUPPLY VOLTAGE
120 - 120 VAC
240 - 240 VAC
All supply voltage tolerances
are 55 to 110 %
TIME-ON DELAY,
TURN CLOCKWISE
TO INCREASE
9/32 (7.14)
3/16 DIA. MOUNTING
TYPICAL 2 PLACES
INDICATING LED
"ON" WHEN RELAY
IS TRIPPED
-
Time-on delay is the time from when
the relay trips to when the output
energizes. The ranges are guaranteed
minimum, actual range may be slightly
greater.
PART NUMBER
TRIP RANGE
.01.1 - .01 to 0.1 AAC
.11 - 0.1 to 1.0 AAC
110 - 1.0 to 10 AAC
330 - 3.0 to 30 AAC
660 - 6.0 to 60 AAC
101 - 10 to 100 AAC
The trip ranges shown are for
one wire pass through the
window opening. The trip range
may be proportionally lowered
with additional wire passes
through the window.
Shown with Remote Current
Transformer Option (-R)
TRIP ON DELAY
A - .5 to 6 Sec.
B - 2 to 25 Sec.
C - .1 - 1 Sec.
X - none
-
73
-
NC NO COM
TRIP POINT DIAL
CD - Calibrated Dial
FP - Fixed Trip Point
(Specify value of fixed
trippoint with order)
-3.30 trip range shown
- CD
-
Electromechanical
dial provided with
No adjustment
ELR
the fixed set
point option
NC NO COM
Relay
- FP
1.65[42.0mm](-100)
1.85[47.0mm(-200)
2.70 [68.6mm](-100)
3.00 [76.2mm](-200)
-
OUTPUT OPTIONS
E-mail: sales@crmagnetics.com
Remote Current Transformers
CRGFS - Series
NPN Transistor
Optoisolated
NPN
Ground Fault Sensor
I - INTERNAL TRANSFORMER
R - REMOTE TRANSFORMER
-
Optoisolated
CR7310 Series
12" [304.8mm](-100 & -200)
TRC
Triac
1.85 [47.0mm](-200)
0.70 [17.8mm](-100)
E