G7L-2A-TUB-80-CB AC200/240 Omron, G7L-2A-TUB-80-CB AC200/240 Datasheet - Page 3

RELAY POWER DPST 25A 240VAC

G7L-2A-TUB-80-CB AC200/240

Manufacturer Part Number
G7L-2A-TUB-80-CB AC200/240
Description
RELAY POWER DPST 25A 240VAC
Manufacturer
Omron
Series
G7Lr
Datasheets

Specifications of G7L-2A-TUB-80-CB AC200/240

Relay Type
General Purpose
Coil Type
Standard
Contact Form
DPST (2 Form A)
Contact Rating (current)
25A
Switching Voltage
250VAC - Max
Coil Current
10.2mA
Coil Voltage
240VAC
Turn On Voltage (max)
150 VAC
Turn Off Voltage (min)
36 VAC
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
25A @ 220VAC
Control On Voltage (max)
150 VAC
Control Off Voltage (min)
36 VAC
Coil Voltage Vac Nom
240V
Contact Current Max
25A
Contact Voltage Ac Nom
220V
Coil Resistance
21000ohm
Contact Configuration
DPST-NO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G7L-2A-TUB-80-CBAC200/240
G7L2ATUB80CBAC200240
■ Contact Ratings
*Note: P level:
■ Characteristics
Note: The values given above are initial values.
Rated load
Rated carry current
Max. switching
voltage
Max. switching
current
Max. switching
power
Failure rate*
(reference value)
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Model
60
= 0.1 x 10
30 A, 220 VAC (~) 25 A, 220 VAC (~) 25 A, 220 VAC (~)
30 A
250 VAC (~)
30 A
6,600 VAC (~)
100 mA, 5 VDC (=)
Resistive load
(cos = 1)
-6
/operation
G7L-1A-T@/G7L-1A-B@
50 m
30 ms max.
30 ms max.
Mechanical:1,800 operations/hr
Electrical:1,800 operations/hr (under rated load)
1,000 M
4,000 VAC min., 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity (DPST-NO model)
10,000 V between coil and contact (with 1.2 x 50 s impulse wave)
Destruction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction:1,000 m/s
Malfunction:100 m/s
Mechanical:1,000,000 operations min. (at 1,800 operations/hr)
Electrical:100,000 operations min. (at 1,800 operations/hr under rated load)
Operating: –25 C to 60 C (with no icing)
Operating: 5% to 85%
Quick-connect terminal models:approx. 90 g
PCB terminal models:approx. 100 g
Screw terminal models: approx. 120 g
5,500 VAC (~)
Inductive load
(cos = 0.4)
max.
min. (at 500 VDC)
2
25 A
25 A
5,500 VAC (~)
2
Resistive load
(cos = 1)
G7L-2A-T@/G7L-2A-B@
Inductive load
(cos = 0.4)
20 A, 220 VAC (~)
20 A
20 A
4,400 VAC (~)
Power Relay
Resistive load
(cos = 1)
G7L-1A-P/G7L-2A-P
G7L
Inductive load
(cos = 0.4)
177

Related parts for G7L-2A-TUB-80-CB AC200/240