ACT112 Panasonic Electric Works, ACT112 Datasheet

no-image

ACT112

Manufacturer Part Number
ACT112
Description
RELAY AUTO MINI 20A 12VDC
Manufacturer
Panasonic Electric Works
Series
ACTr
Datasheet

Specifications of ACT112

Relay Type
Automotive
Contact Form
SPDT (1 Form C)
Contact Rating (current)
20A
Switching Voltage
14VDC - Nom
Coil Type
Standard
Coil Current
66.7mA
Coil Voltage
12VDC
Turn On Voltage (max)
7.2 VDC
Turn Off Voltage (min)
1 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
20A @ 12VDC
Control On Voltage (max)
7.2 VDC
Control Off Voltage (min)
1 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2591
ACT112

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACT112
Manufacturer:
PANASONIC
Quantity:
5 400
Part Number:
ACT112
Manufacturer:
NAIS
Quantity:
20 000
Part Number:
ACT112 M09
Manufacturer:
PANASONIC
Quantity:
5 400
Part Number:
ACT112-M09-12V
Manufacturer:
UK
Quantity:
5 400
Part Number:
ACT11244
Manufacturer:
ACTEL
Quantity:
10
Part Number:
ACT11244
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
ACT11245
Manufacturer:
MFR
Quantity:
3
Twin type (8 terminals)
mm
SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
*
*
*
*
*
*
*
*
*
1
2
3
4
5
6
7
8
9
Arrangement
Contact material
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1 A)
Rating
Expected life
(min. operation)
Nominal operating power
Compliance with RoHS Directive
and desired reliability level, therefore it is recommended to check this with the
actual load.
At nominal switching capacity, operating frequency: 1s ON, 9s OFF
N.O.: at 5 A (steady), 25 A (inrush)/N.C.: at 20 A (brake) 14 V DC, operating
frequency: 0.5s ON, 9.5s OFF
At 25A 14 V DC (Motor lock), operating frequency: 0.5s ON, 9.5s OFF
Measurement at same location as “Initial breakdown voltage” section
Detection current: 10mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
inch
17.4
.685
Nominal switching
capacity
Max. carrying current
(N.O.)
Min. switching capacity
Mechanical (at 120 cpm)
Electrical
14
.551
13.5
.531
17.4
.685
Slim 1c type
Resistive load
Motor load
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
13.5
.531
#1
.283
7.2
Ag alloy (Cadmium free)
(14 V, at 85 C
(14 V, at 20 C
N.O.: 20 A 14 V DC
N.C.: 10 A 14 V DC
35 A for 2 minutes,
30 A for 2 minutes,
Min. 2 10
Typ. 10 m
Typ. 7 m
Min. 10
25 A for 1 hour
20 A for 1 hour
FEATURES
• Small & slim size
Twin type: 17.4(L) 14.0(W) 13.5(H)mm
.685(L) .551(W) .531(H)inch
Slim 1c type: 17.4(L) 7.2(W) 13.5(H)mm
.685(L) .283(W) .531(H)inch
• Twin (1 Form C
Forward/reverse motor control is possible
with a single relay.
• Simple footprint enables ease of PC
board layout
1 Form C 2,
1 A 12 V DC
Min. 10
1 Form C
Min. 10
800 mW
AUTOMOTIVE RELAY
5
SUPER MINIATURE
*
5
3
*
2
(N.O.)
(lock)
5
(N.C.)
7
*
185
(free)
1
68
10 terminals layout
TWIN TYPE
F)
F)
Contact
terminal
= 8 terminals
2)
Characteristics
*
*
* If the relay is used continuously for long periods of time with coils on both sides
Max. operating speed
(at nominal switching capacity)
Initial insulation resistance*
Initial
breakdown
voltage*
Operate time*
(at nominal voltage) (at 20 C
Release time*
(at nominal voltage) (at 20 C
Shock resistance
Vibration
resistance
Conditions for
operation, transport and
storage*
and condensing at low
temperature)
Mass
10
11
Coil
terminal
Time of vibration for each direction;
Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT .
Please inquire if you will be using the relay in a high temperature atmosphere
(110 C
in an energized condition, breakdown might occur due to abnormal heating
depending on the carrying condition. Therefore, please inquire when using with
a circuit that causes an energized condition on both sides simultaneously.
X
5
11
230
Y
(Not freezing
Z
F).
Between open
contacts
Between contacts
and coil
6
X, Y, direction: 2 hours
Z direction: 4 hours
6
Functional*
Destructive*
Functional*
Destructive*
TYPICAL APPLICATIONS
• Power windows
• Auto door lock
• Power sunroof
• Electrically powered mirrors
• Powered seats
• Lift gates
• Slide door closers, etc.
CT RELAYS (ACT)
Ambient
temp
Humidity
(for DC motor forward/reverse control
circuits)
4
68
68
7
9
8
10
F)
F)
Approx. 4.0g
Approx. 8.0g
Min. 100 M
Min. 1,000 m/s
5% R.H. to 85% R.H.
Min. 44.1m/s
Min. 44.1m/s
Min. 100 m/s
500 Vrms for 1 min.
500 Vrms for 1 min.
Max. 10ms (Initial)
Max. 10ms (Initial)
10 Hz to 100 Hz,
10 Hz to 500 Hz,
–40 F to +185 F
–40 C to +85 C
.14oz
6 cpm
.28oz
CT (ACT)
(at 500 V DC)
2
2
(Slim 1c type)
2
2
{4.5G}
{4.5G}
{10G}
(Twin type)
{100G}

Related parts for ACT112

ACT112 Summary of contents

Page 1

... Half-wave pulse of sine wave: 11ms; detection Half-wave pulse of sine wave: 6ms * 9 Detection time All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. SUPER MINIATURE TWIN TYPE AUTOMOTIVE RELAY FEATURES • Small & slim size Twin type: 17.4(L) 14.0(W) 13.5(H)mm .685(L) .551(W) .531(H)inch Slim 1c type: 17 ...

Page 2

... Standard packing; 1 Form C: Carton(tube package) 30pcs. Case 1,500pcs. 1 Form C 2: Carton(tube package) 30pcs. Case 900pcs. TYPES AND COIL DATA ( Nominal Contact Part No. voltage, arrangement ACT112 1c 2 ACT212 (8 terminals type ACT512 (10 terminals type) * Other pick-up voltage types are also available. Please contact us for details. DIMENSIONS 1 ...

Page 3

... Ambient temperature and operating voltage range Pick-up voltage (Cold start) 0 –40 – 100 120 Ambient temperature, C All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 7.2 17.4 .685 .283 Max. 1.0 .039 *A 0 .031 .039 0.4 0.4 0.3 .039 .016 .016 .012 9.5 ...

Page 4

... No. of operations, 10 Change of pick-up and drop-out voltage 10 Contact welding: 0 time Miscontact: 0 time 8 Pick-up voltage 6 4 Drop-out voltage No. of operations, 10 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Change of contact resistance 50 40 Max Min. 20 Max. X Min No. of operations, Change of contact resistance ...

Page 5

... M M Side2 Relay 1 Relay 2 0.3s 9.7s 0.3s 9.7s 20s (1 cycle) Load current waveform 5A 100ms For Cautions for Use, see Relay Technical Information. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Change of pick-up and drop-out voltage Pick-up voltage Max Min Drop-out voltage 3 Max ...

Related keywords