CA1A-DC24V-N Panasonic Electric Works, CA1A-DC24V-N Datasheet - Page 6

no-image

CA1A-DC24V-N

Manufacturer Part Number
CA1A-DC24V-N
Description
RELAY AUTO 24VDC 1.8MW SCREW MNT
Manufacturer
Panasonic Electric Works
Series
CAr
Datasheet

Specifications of CA1A-DC24V-N

Relay Type
Automotive
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
10A
Switching Voltage
24VDC
Coil Type
Standard
Coil Current
75mA
Coil Voltage
24VDC
Turn On Voltage (max)
16 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Chassis Mount
Termination Style
Socketable
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
10A @ 24VDC
Control On Voltage (max)
16 VDC
Control Off Voltage (min)
1.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7-(2). Electrical life test (Lamp load)
Sample: CA1a-12V-C, 3pcs.
Load: 60Wx4, Inrush current: 110A, steady current: 20A
Halogen lamp actual load
Switching frequency: (ON:OFF = 1s:14s)
Ambient temperature: Room temperature
Load current waveform
Load: Inrush current: 110A, steady current: 20A,
Cautions regarding the protection element
1. Part numbers without protection
elements
1) 12 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 24 V
or higher, or a resistor (680 to 1,000 ).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
2) 24 V models
When connecting a coil surge protection
circuit to these relays, we recommend a
Zener diode with a Zener voltage of 48 V
or higher, or a resistor (2,800 to
4,700 ).
When a diode is connected to the coil in
parallel, the release time will slow down
and working life may shorten. Before use,
please check the circuit and verify that
the diode is not connected in parallel to
the coil drive circuit.
For Cautions for Use, see Relay Technical Information.
20A
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
200ms
Change of pick-up and drop-out voltage
2. Part numbers with diodes
These relays use a diode in the coil surge
protection element. Therefore, the
release time is slower and the working life
might be shorter compared to part
numbers without protection elements and
part numbers with resistors.
Be sure to use only after evaluating under
actual load conditions.
3. Part numbers with resistors
This part number employs a resistor in
the coil surge protection circuit; therefore,
an external surge protection element is
not required. In particular, when a diode
is connected in parallel with a coil, the
revert time becomes slower which could
adversely affect working life. Please
check the circuit and make sure that a
diode is not connected in parallel with the
coil drive circuit.
10
9
8
7
6
5
4
3
2
1
0
0
Drop-out voltage
No. of operations,
Pick-up voltage
10
10
4
20
Max.
X
Min.
Max.
X
Min.
Change of contact resistance
10
9
8
7
6
5
4
3
2
1
0
0
No. of operations,
10
10
4
20
CA
Max.
Min.
X

Related parts for CA1A-DC24V-N