DJ (ADJ)
SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
*
*
*
*
*
*
*
*
*
*
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Expected
life (min.
operations)
Nominal operating
power
1
2
3
4
5
6
7
8
9
10
Without test button
and desired reliability level, therefore it is recommended to check this with the
actual load.
With breathing holes open
Measurement at same location as “Initial breakdown voltage” section.
Detection current: 10mA
Wave is standard shock voltage of 1.2
Excluding contact bounce time.
By resistive method, max. switching current
Half-wave pulse of sine wave: 11 ms; detection time: 10 s
Half-wave pulse of sine wave: 6 ms
Detection time: 10 s
Nominal switching
capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity
Mechanical
(at 180 cpm)
Electrical
(Resistive load)*
(at 20 cpm)
1 coil latching
Single side stable, 2 coil latching
With test button
1
#1
(1 Form C, 1 Form A, 1 Form B)
50 s according to JEC-212-1981
(2 Form C, 2 Form A, 2 Form B,
1 Form C, 1 Form A, 1 Form B,
1 Form C, 1 Form A, 1 Form B:
2 Form C, 2 Form A, 2 Form B,
1 Form A 1 Form B, 2 Form C,
POWER LATCHING RELAY
10
10
1 Form A 1 Form B: :
1 Form A 1 Form B)
2 Form A, 2 Form B
5
5
100 mA, 5 V DC
16 A 250V AC
10 A 250V AC
(at 16A 250V AC)
(at 10A 250V AC)
16A, COMPACT AND
Silver alloy
4,000 V A
HIGH INSULATION
250V AC
FEATURES
1. Variety of contact arrangements
Wide lineup of 1 Form C, 1 Form A,
1 Form B, 2 Form C, 2 Form A, 2 Form B,
1 Form A 1 Form B.
2. Latching operation
Latching via a polarized magnetic circuit
structure allows remote operation and
lower energy consumption
3. Compact with high capacity
16A (1-pole type) contact rating in a
compact 29 13 16.5 mm (L W H) size.
4. Low power consumption
1 coil latching: 150mW
2 coil latching, single side stable: 250mW
5. High insulation
Both clearance and creepage distance
between coil and contact are at 8 mm
min.
100 m
5 10
16 A
6
250mW
150mW
Characteristics
Initial insulation resistance*
Initial
breakdown
voltage*
Surge voltage between contact and
coil*
Operate time [Set time]*
(at nominal voltage)
Release time [Reset time]*
(at nominal voltage)
Temperature rise (at 70 C)*
Shock
resistance
Vibration
resistance
Conditions for
operation, transport
and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
4
3
10
Between open
contacts
Between contacts and
coil
DJ RELAYS
Functional*
Destructive*
Functional*
Destructive
Ambient
temperature
Humidity
5
5. With operation veri cation function
A test button (manual lever) type to
facilitate circuit checks is also available
(1 Form C, 1 Form A, 1 Form B types
only).
TYPICAL APPLICATIONS
• FA equipment (brake circuits of
• Electric power devices (remote
• Household appliance networks (Motor
• Time switches
industrial machine and robots, etc.)
surveillance devices, etc.)
control and lighting control, etc.)
5
2
6
(ADJ)
7
9
8
at double amplitude of 2.0mm
at double amplitude of 3.0mm
Min. 1,000 M
Min. 1,000 m/s
1,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V (initial)
Min. 200 m/s
Approx. 14 g
–40 F to +158 F
–40 C to +70 C
5 to 85% R.H.
Approx. 10ms
Approx. 10ms
10 to 55Hz
10 to 55Hz
Max. 55 C
(at 500 V DC)
2
2
{20 G}
.49 oz
{100 G}
pending
VDE