HP2-DC48V Panasonic Electric Works, HP2-DC48V Datasheet - Page 6

no-image

HP2-DC48V

Manufacturer Part Number
HP2-DC48V
Description
RELAY POWER 10A 48VDC PLUG-IN
Manufacturer
Panasonic Electric Works
Series
HPr
Datasheet

Specifications of HP2-DC48V

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
10A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
26.7mA
Coil Voltage
48VDC
Turn On Voltage (max)
38.4 VDC
Turn Off Voltage (min)
7.2 VDC
Mounting Type
Socket
Termination Style
Quick Connect - .205" (5.2mm)
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
38.4 VDC
Control Off Voltage (min)
7.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HP2-DC48V
Manufacturer:
PANASONIC
Quantity:
12 000
HP
4. Life of LED and neon lamp (with operation indication)
REFERENCE DATA
1. Life curve
DIMENSIONS
Plug-in type (2 Form C)
1,000
900
800
700
600
500
400
300
200
100
0
With LED indication
With neon lamp
Mechanical life
more than 10,000,000
operations
With LED indication
With neon lamp
5
Load current, A
(Unit: mm inch)
10
Neon lamp
LED
.031
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
0.8
5.26 5.26
.207 .207
8
7
6
5
.984
.591
.394
25
15
10
2. Max. switching capacity
.031
1
2
3
4
0.8
External dimensions
50,000 hours (approx. 5.5 years)
.276
25,000 hours (approx. 3 years)
44
1.732
7
0.1
5.26
.207
5.26
.207
10
0.8
.031
0.8
.031
1
51
2.008
10
0.5
.020
DC inductive
load
(L/R=7ms)
.209
5.3
9.5
.374
7.5
.295
5.8
.228
Continuous
36
1.417
AC inductive load
(cos =0.4)
(Coil terminal No.)
(Coil terminal No.)
Contact voltage, V
Schematic
Schematic
100
LED
Protection diode
DC resistive
load
.197.315 .197
AC resistive load
5
Dimension:
Max. 2mm
2 to 9mm
9 to 20mm
Min. 20mm
8
500 1,000
5
Compatible with tab terminal
#205 series receptacle.
.079 to .354
.079
.354 to .787
.787
inch:
inch:
Coil terminal No. and polarity (DC type)
Terminal
inch:
No.
inch:
100,000 hours (approx. 11 years)
Use rating (ON time) 50%
Schematic (Bottom view)
Tolerance
0.2
0.5
1
1.5
Polarity
Approx. 6 years
(+)
(–)
.008
.020
.039
.059
8
7
6
5
HP2
7
2
4
3
1
2
HP3
10
2
HP4
10
1