SF4D-DC60V Panasonic Electric Works, SF4D-DC60V Datasheet

RELAY SAFETY 6A 60VDC PCB

SF4D-DC60V

Manufacturer Part Number
SF4D-DC60V
Description
RELAY SAFETY 6A 60VDC PCB
Manufacturer
Panasonic Electric Works
Series
SFr
Datasheet

Specifications of SF4D-DC60V

Relay Type
Safety
Contact Form
8PST (4 Form A, 4 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
8.3mA
Coil Voltage
60VDC
Turn On Voltage (max)
45 VDC
Turn Off Voltage (min)
9 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
8PST (4 Form A, 4 Form B)
Contact Rating @ Voltage
6A @ 250VAC
Control On Voltage (max)
45 VDC
Control Off Voltage (min)
9 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ds_61407_en_sf4d: 011010D
SPECIFICATIONS
Contact
Coil
Remarks
*1 According to EN 60947-5-1: 1997, table 4 AC15 / DC13
*2 Contact interruption <10s
*3 Breathing hole open
ORDERING INFORMATION
Ex. SF4D
Contact configuration (a = normally open / NO,
b = normally closed / NC)
Contact material
Contact resistance (initial at 6V DC, 1A)
Making and breaking capacities (breathing
hole open)
Max. switching voltage
Min. switching voltage / min. switching current
Pick-up / drop-out / bounce time
(approx. values at U
Mechanical life
Operate / release voltage (% of U
20°C)
Pick-up/nominal power consumption at 20°C
Tolerance 0.3mm
Weight approx. 47g
Note: Standard packing; Carton: 20 pcs. Case 200 pcs.
Coil voltage (DC)
*1
5, 9, 12, 18, 21
24, 36, 48, 60
DC12 V
53.3
nominal
)
nominal
at
length: 3.0
33
AgSnO
POLARIZED, MONOSTABLE
6A 250V / 3A 24V
18.5 / 7.5 / 3ms
16.5
280 / 500mW
10V / 10mA
75% / 15%
SAFETY RELAY WITH
2
10
DOUBLE CONTACTS
, with Au flash
4a4b
30m
400V
FORCIBLY GUIDED
7
ops
Features
• Relay complies with EN 50205, Type B
• Overvoltage category as per IEC 60664-1 III / 4kV
• Rated voltage
as per IEC 60664-1
basic insulation
Coil-contact
Contact-contact
Characteristics
Important: Relay characteristics may be influenced by:
• strong external magnetic fields
• magnetic conductive materials near the relay
• narrow top-to-top mounting (printed surface to printed surface)
Note:
Suitable for most common washing methods except ultrasonic cleaning.
Max. switching frequency (without load)
Permissible ambient temperature at nominal
power consumption
Upper temperature limit
Test voltage:
open contact / contact-contact / contact-coil
Insulation resistance at 500V DC (initial)
Shock resistance (11ms) NO/NC
Vibration resistance 10 – 200 Hz (10 – 55 Hz,
amplitude 2 mm)
Degree of protection
Unit weight
forcibly linked
pair only
all other
contacts
*2
inside
400V
250V
400V
2
Polution degree
outside
*2
400V
250V
400V
RELAY
2
SF4D
inside
250V
250V
400V
3
-40°C to +70°C
2500 / 2500 /
IP67 / IP30
2500V
105°C
10Hz
10
30G
10G
47g
SF4D
9
rms
*3
1

Related parts for SF4D-DC60V

SF4D-DC60V Summary of contents

Page 1

... Pick-up/nominal power consumption at 20°C Remarks *1 According to EN 60947-5-1: 1997, table 4 AC15 / DC13 *2 Contact interruption <10s *3 Breathing hole open ORDERING INFORMATION Ex. SF4D DC12 V Coil voltage (DC 12, 18, 21 24, 36, 48, 60 Note: Standard packing; Carton: 20 pcs. Case 200 pcs. ds_61407_en_sf4d: 011010D ...

Page 2

... SF4D COIL DATA Coil nominal voltage Part number V DC SF4D-DC5V 5 SF4D-DC9V 9 SF4D-DC12V 12 SF4D-DC18V 18 SF4D-DC21V 21 SF4D-DC24V 24 SF4D-DC36V 36 SF4D-DC48V 48 SF4D-DC60V 60 ELECTRICAL LIFE Voltage Current 230V AC 8A 250V AC 6A 230V AC 6A 230V 24V DC 8A 24V DC 3A 24V 60947-5-1: 1997; table C.1 *2 Breathing hole closed *3 Breathing hole open *4 Ambient temperature +70° ...

Page 3

... APPLICATION NOTES Actuator Nipple If required a breathing hole can be made in the cover by removing the nipple. However be aware that the degree of protection will reduce from IP67 to IP30! ds_61407_en_sf4d: 011010D 100 110 your local Panasonic Electric Works representative. External dimensions 16±0.5 .630±.020 ...

Page 4

... If an inner contact should weld, then the movement of the rotating armature is blocked via the actuator. Open contacts of all four contact pairs remain open. This arrangement corresponds to a conventional forcibly guided contact operation. Actuator Outer contact Inner contact Rotating armature For Cautions for Use, see 4 Relay Technical Information. ds_61407_en_sf4d: 011010D ...

Related keywords