8430230000 Weidmuller, 8430230000 Datasheet - Page 79

no-image

8430230000

Manufacturer Part Number
8430230000
Description
RELAY DISCRETE 12/24VDC GN
Manufacturer
Weidmuller
Datasheet

Specifications of 8430230000

Relay Type
General Purpose
Contact Form
DPST (2 Form A)
Contact Rating (current)
5A
Switching Voltage
250VAC
Coil Type
Standard
Coil Voltage
24VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
5A @ 250VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Control On Voltage (max)
-
Control Off Voltage (min)
-
Other names
WRS2 12/24VDC/DC 2A
Continuous
current
136
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Output supply voltage
Voltage drop at max. load current
Output current
Derating curve
a = rowed on mounting rail without clearances
b = rowed with clearances ≥ 20 mm
Pulse duration, limiting overload current (not periodic)
Sperrstrom (Ruhestrom), max. at U = 48 V
Switch-on time (cyclic operation)
Switch-off time (cyclic operation)
Max. switching frequency DC voltage
Max. switching frequency AC voltage
Switching ratio
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Opto-coupler
Test voltage (corresponds 100% module test)
Module is immune to interference
Insulation voltage
Input – output/mounting rail
Storage temperature
Ambient temperature
–, rowed on mounting rail without clearances
–, rowed with clearances ≥ 20 mm
Rated data
Insulation coordination to EN 50 178
Opto-coupler on locking socket profile RS 40
Opto-couplers
for signal input
Ambient temperature
1
2
5 V–
0.045 W
5…48 V–
< 0.9 V
20 mA
0.2 A/10 ms
0.16 mA
≤ 12 µs
≤ 15 µs
3 kHz
1 : 2
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4
severity 4
4 kV~
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
RS 40
) Not TTL-compatible
) Conditionally level-compatible
2
)
eff
1 min.
1
)
12 V0 ± 10 %
0.25 W
0.32 VA
5…48 V–
< 1.6 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 6 ms
≤ 13 ms
20 Hz
< 10 Hz
10 Hz 1 : 2
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
20 or 100
24 V– ± 10 %
0.51 W
5…48 V–
< 0.9 V
20 mA
0.2 A/10 ms
0.16 mA
≤ 30 µs
≤ 60 µs
3 kHz
1 : 2
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
24 V0 ± 10 %
0.34 W
0.5 VA
5…48 V–
< 1.6 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 2 ms
≤ 15 ms
20 Hz
10 Hz 1 : 1
300 V
6 kV
III
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
48 V0 ± 10 %
0.55 W
0.65 VA
5…48 V–
< 1.6 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 5 ms
≤ 20 ms
< 20 Hz
< 10 Hz
10 Hz 1 : 1
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
20 or
100
115 V0, +5%-15% 230 V~, +5%-15%
0.33 W
0.65 VA
5…48 V–
< 1.5 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 10 ms
≤ 23 ms
10 Hz
10 Hz 1 : 1
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
4 kV~
–40 °C…+70 °C
–25 °C…+40 °C
–25 °C…+45 °C
eff
1 min.
1
)
0.52 VA
5…48 V–
< 1.5 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 6 ms
≤ 18 ms
10 Hz 1 : 1
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)