SPECIFICATIONS
Contacts
Coil (at 25°C 77°F, 50% R.H.)
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
• Interface relays for programmable
• Output relays for measuring equipment,
• Industrial equipment, office equipment
• House-hold appliances for Europe
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Rating
(resistive)
Expected life
(min.
operations)
Nominal operating power
1
2
3
4
5
6
7
8
controllers
timers, counters and temperature
controllers
Measurement at same location as “Intial breakdown voltage” section
Detection current: 10mA
Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
Excluding contact bounce time
Half-wave pulse of sine wave: 50ms; detection time: 10µs
Half-wave pulse of sine wave: 11ms
Detection time: 10µs
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
and desired reliability level, therefore it is recommended to check this with the
actual load.
Nominal switching capacity
Maximum switching power
Maximum switching voltage
Max. switching current
Min. switching capacity
Mechanical (at 180 cpm)
Electrical (at 6 cpm)
(at rated load)
1.102
28
.591
.197
15
5
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
#1
THE SLIM POWER RELAY
170 mW (4.5 to 24 V DC)
Silver alloy
100 mA,
100 mΩ
5 V DC
1 Form A, 1 Form C
217 mW (48 V DC)
FEATURES
• Slim size
• Wide switching capacity:
• High sensitivity: 170mW
• High breakdown (4,000 V) and surge
• Clearance/creepage distance:
• 1 Form A/1 Form C contact.
ORDERING INFORMATION
(Notes) 1. Standard packing: Tube: 20 pcs.; Case: 1,000 pcs.
6 A 250 V AC
N.O.: 5×10
N.C.: 3×10
28 mm (L)×5 mm (W)×15 mm (H)
1.102 inch (L)×.197 inch (W)×.591 inch
(H)
permits high density mounting
100 mA/12 V DC-6A/250 V AC
(6,000 V) voltage between contacts
and coil
8/8 mm
Contact arrangement
1,500 VA
250V AC
6 A (AC)
5×10
1: 1 Form A
3: 1 Form C
2. 5 V, 60 V type is also available.
silver alloy
Au-plated
6
1 V DC
30 mΩ
1 mA,
4
4
Ex.
APE
Characteristics
Initial insulation resistance*
Initial
breakdown
voltage*
Surge voltage between contacts and
coil*
Operate time*
Release time (without diode)*
(at nominal voltage)
Temperature rise
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and condens-
ing at low temperature)
Unit weight
0: Single contact
Contact type
3
2
Between open contacts
Between contacts and
coil
4
(at nominal voltage)
0
8
0: Silver alloy
1: Au-plated silver alloy
PE RELAYS
Functional*
Destructive*
Functional*
Destructive
Ambient
temp.
Humidity
Contact material
Insulation complying to following standards:
EN 60255 General specification for electrical relays
EN 60335 For use in house-hold appliances
EN 60730 For use in temperature sensing
appliances
EN 60950 For use in electrical business equipment
EN 60065 For use in entertainment electronics
(radio, HiFi-sets)
EN 50178 For use in industrial range
1
4
(APE)
5
7
6
at double amplitude of 1.0 mm/6 G
at double amplitude of 1.5 mm/9 G
1 Form A: Min. 98 m/s
coil and at nominal switching
1 Form C: Min. 49 m/s
Min. 1,000 MΩ at 500 V DC
Max. 30°C with nominal coil
Max. 4 ms (approx. 2.5 ms)
Max. 8 ms (approx. 5 ms)
Min. 980 m/s
Min. 6,000 V (Initial)
Approx. 4 g
–40°F to +185°F
–40°C to +85°C
voltage across
5 to 85%R.H.
4H: 4.5 V
06: 6 V
12: 12 V
1,000 Vrms
10 to 55 Hz
10 to 55 Hz
4,000 Vrms
Coil voltage (DC)
capacity
PE (APE)
2
.14 oz
{100 G}
18: 18 V
24: 24 V
48: 48 V
2
2
{10 G}
{5 G}
VDE