AGQ2004H Panasonic Electric Works, AGQ2004H Datasheet - Page 5

RELAY PWR PC MNT DPDT 1A 4.5VDC

AGQ2004H

Manufacturer Part Number
AGQ2004H
Description
RELAY PWR PC MNT DPDT 1A 4.5VDC
Manufacturer
Panasonic Electric Works
Series
AGQr
Type
General Purpose Relayr
Datasheets

Specifications of AGQ2004H

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Standard
Coil Current
31mA
Coil Voltage
4.5VDC
Control On Voltage (max)
3.38 VDC
Control Off Voltage (min)
0.45 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Brand/series
AGQ Series
Contact Form
DPDT
Current, Rating
1⁄0.3 AAC⁄ADC
Dimensions
0.417 in. +⁄- 0.012 in. L x 0.283 in. +⁄- 0.012 in. W x 0.205 in. +⁄- 0.008 in. H
Function
Sensitive
Latch Type
Single Side Stable
Material, Contact
AgPd + Au Clad (Stationary), AgPd (Movable)
Number Of Pins
8
Power, Rating
30 W
Standards
UL, CSA
Termination
Solder
Voltage, Control
4.5 VDC
Voltage, Rating
125 VAC
Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
4.5V
Voltage Rating (vdc)
110V
Voltage Rating (vac)
125V
Dropout Volt (min)
0.45VDCV
Coil Resistance
145Ohm
Pick-up Voltage (max)
3.38VDC
Maximum Power Rating
30W/37.5VA
Operate Time
4ms
Contact Current Rating
1A
Contact Material
AgPd
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
5.2mm
Product Depth (mm)
7.2mm
Product Length (mm)
10.6mm
Operating Temp Range
-40C to 85C
Pin Count
8
Mounting Style
Through Hole
Package / Case
DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1357-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AGQ2004H
Manufacturer:
YEONHO
Quantity:
30 000
Company:
Part Number:
AGQ2004H
Quantity:
3 888
2. Surface-mount terminal
Schematic (Top view)
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
High sensitivity single side stable
CAD Data
GQ relays
Stopper (green)
Stopper (green)
A type
S type
Relay polarity bar
(Z type)
Type
(Deenergized condition)
Single side stable
Orientation (indicates PIN No.1) stripe
Orientation (indicates PIN No.1) stripe
Direction indication
Tape coming out direction
8
1
General tolerance 0.1 mm
1.50
.059
7
2
Single side stable/1 coil latching/High sensitivity single side stable
12.0
.472
6
3
+0.1
+.003
0
.0
.079
Max. 5.40
Max. 5.40
.016 .004
.016 .004
5
4
2.0
dia.
dia.
0.40 0.1
0.40 0.1
3.20 0.15
.126 .006
3.20 0.15
.126 .006
.213
.213
.354
9.0
4.00
.157
2.00 dia.
.079 dia.
10.60 0.3
.417 .012
10.60 0.3
.417 .012
1.75
.069
11.5
.453
11.1
.437
.004 inch
Stopper (red)
Stopper (red)
24.0 0.3
.945 .012
2.20 0.15
.087 .006
2.20 0.15
.087 .006
Max. 6.55
External dimensions
2.20 0.15
.087 .006
2.20 0.15
.087 .006
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
mm
0.40
.016
.256
inch
.008 .004
0.20 0.1
(Reset condition)
Direction indication
1 coil latcing
(S type)
(1)-2 Tape dimensions
(2) Dimensions of plastic peel
8
1
GQ relays
Relay polarity bar
(Z type)
7.20 0.3
.283 .012
7.20 0.3
.283 .012
7.20 0.3
.283 .012
7
2
6
3
5
4
.079
0.20 0.1
.008 .004
5.08 0.15
.200 .006
2.0
5.08 0.15
.200 .006
Tape coming out direction
8.40 0.3
.331 .012
General tolerance 0.1 mm
1.50
.059
12.0
.472
+0.1
+.003
0
.0
.079
2.0
dia.
dia.
21 dia.
.827 dia.
13 dia.
.512 dia.
.307
7.8
4.0
.157
2.00 dia.
.079 dia.
1.75
.069
11.1
.437
11.5
.453
.004 inch
.945 .012
Single side stable/1 coil latching/High sensitivity single side stable
24.0 0.3
80 1 dia.
3.150 .039 dia.
330 2 dia.
12.992 .079 dia.
Max. 6.55
mm
.256
Suggested mounting pad (Tolerance: 0.1 .004)
inch
0.40
.016
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A :
9.8 N {1 kgf} or less
Chucking pressure in the direction B :
9.8 N {1 kgf} or less
Chucking pressure in the direction C :
9.8 N {1 kgf} or less
Please chuck the
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be also
avoided.
3.20
.126
3.20
.126
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
0.80
.031
0.80
.031
2.20
.087
2.20
.087
2.20
.087
2.20
.087
2.66 6.74
.105 .265
2.06
.081
A
6.14
.242
C
GQ (AGQ)
portion.
B

Related parts for AGQ2004H