ASX21012 Panasonic Electric Works, ASX21012 Datasheet - Page 5

RELAY LATCHING 10MA 12VDC PCB

ASX21012

Manufacturer Part Number
ASX21012
Description
RELAY LATCHING 10MA 12VDC PCB
Manufacturer
Panasonic Electric Works
Series
ASXr
Datasheet

Specifications of ASX21012

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
0.01A @ 10VDC
Coil Type
Latching, Single Coil
Coil Current
2.9mA
Coil Voltage
12VDC
Control On Voltage (max)
9.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Other names
255-1581
255-1581-5
255-1581

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ASX21012
Manufacturer:
Panasonic Electric Works
Quantity:
135
Part Number:
ASX21012
Manufacturer:
Panasonic
Quantity:
12 000
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
2) Tape and reel packing
(A type)
(1) Tape dimensions
(2) Dimensions of plastic reel
Relay polarity bar
(Z type)
Stopper (gray)
SX relays
.512 dia.
13 dia.
Orientation (indicates PIN No.1)stripe
.079
Tape coming out direction
2.0
.059
1.5
+0.1
+.004
0
0
21 dia.
.827 dia.
dia.
dia.
.630
16.0
.079
2.0
.157
4.0
10.0
.394
Stopper (green)
15.5
.610
24.0
.945
11.5
.453
80 dia.
3.150 dia.
1.75
.069
380 dia.
14.961 dia.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
mm
mm
0.3
.012
10.8
.425
.016
0.4
inch
inch
0.2
.008
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
Please chuck the
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
A
C
portion.
B
SX (ASX)