G5V-1-2 DC12 Omron, G5V-1-2 DC12 Datasheet - Page 2

RELAY PCB SPDT 1A 12VDC

G5V-1-2 DC12

Manufacturer Part Number
G5V-1-2 DC12
Description
RELAY PCB SPDT 1A 12VDC
Manufacturer
Omron
Series
G5V-1r
Datasheet

Specifications of G5V-1-2 DC12

Coil Type
Standard
Coil Current
12.5mA
Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
1A @ 24VDC
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Configuration
SPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
24V
Coil Voltage Vdc Nom
12V
Contact Form
1 Form C
Power Consumption
150 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G5V-1-2-DC12
G5V12DC12
■ Coil Data
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
■ Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Note: In the interest of product improvement, specifications are subject to change.
46
3
5
6
9
12
24
Contact resistance (See note 1)
Operate time (See note 2)
Release time (See note 2)
Operating frequency (max.)
Insulation resistance (See note 3)
Dielectric strength
Impulse withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
G5V-1
voltage
Rated
(VDC)
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC Megohmmeter between coil and contacts and a 250 VDC megohmmeter between con-
4. The above values are initial values.
tacts with the same polarity applied to the same parts as those for checking the dielectric strength.
Type
Low Signal Relay
Rated current
50
30
25
16.70
12.50
6.25
(mA)
SPDT
Contact form
60
167
240
540
960
3,840
resistance
Coil
(Ω)
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 3.30 mm double amplitude
Malfunction durability
Mechanical durability 1,000 m/s
Malfunction durability 100 m/s
Mechanical
Electrical
G5V-1
0.05
0.15
0.20
0.45
0.85
3.48
Armature OFF
3 to 24 VDC
Coil inductance
(Ref. value) (H)
Coil rating
100 mΩ max.
5 ms max. (mean value: approx. 2.50 ms)
5 ms max. (mean value: approx. 0.90 ms)
36,000 operations/hour
1,800 operations/hour
1,000 MΩ min. (at 500 VDC between coil and contacts, at 250 VDC between
contacts of same polarity)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
400 VAC, 50/60 Hz for 1 minute between contacts of same polarity
1,500 V (10 X 160 μs) between coil and contacts (conforms to FCC Part 68)
-40°C to 70°C
5% to 85% RH
5 million operations min. (at 18,000 operations/hour)
100,000 operations min. (under rated load,1,800 ops/hr) See “Characteristic Data”
Approx. 2 g
0.11
0.29
0.41
0.93
1.63
6.61
Armature ON
2
(approx. 10 G)
2
(approx. 100G)
0.5A at 125 VAC (General Use)
0.3 A at 110 VDC (Resistive)
1A at 30 VDC (Resistive)
80%
Pick-up
voltage
Contact ratings
% of rated voltage
10% min.
Dropout
voltage
100,000
6,000
200%
at 23°C
Number of test operations
Maximum
voltage
Approx. 150
consumption
Power
(mW)

Related parts for G5V-1-2 DC12