Page 1
... Fully sealed PCB terminal Surface-mounting terminal 1. When ordering, add the rated coil voltage to the model number. Note: Example: G6L-1P 12 VDC Rated coil voltage 2. When ordering tape packing, add “-TR” to the model number. Example: G6L-1F-TR 12 VDC Tape packing Be sure since “-TR” is not part of the relay model number not marked on the relay case. ...
Page 2
... Rated load 1 A Rated carry current 125 VAC, 60 VDC Max. switching voltage Max. switching current 1 A Coil Ratings I Single-side Stable Relays (G6L-1P, G6L-1F) 3 VDC Rated voltage Rated current 60.0 mA Coil resistance 50.0 Ω Must operate voltage 75% max. of rated voltage Must release voltage 10% min ...
Page 3
... Relays to check the number of contact malfunctions. Contact Reliability Test (Contact Resistance) (See notes 1 and 2.) 1,000 Sample: G6L-1F NO contact Number of Relays: 10 Test conditions: 1-A resistive load at 500 24-VDC with an operation rate of 50% Switching frequency: 1,800 operations/h ...
Page 4
... Frequency (MHz) G6L (Average value) + +20 +10 0 −10 −20 Must operate voltage Sample: G6L-1F Must release voltage Number of Relays: 5 −30 0 400 800 1,200 −1,200 −800 −400 External magnetic field (A/m) High-frequency Characteristics (Return Loss, V.SWR) (See note.) (Average value ...
Page 5
... Each value has a tolerance of ±0.3 mm. 10.6 ±0.2 7 ±0.2 0.4 8.4 1.49 5.08 7.62 Note: Each value has a tolerance of ±0.3 mm. Vibration Resistance 5.0 Sample: G6L-1F Number of Relays: 5 4.0 3.0 2.0 1.0 Must release voltage 0.0 -1.0 Must operate voltage -2.0 -3.0 -4.0 -5.0 ...
Page 6
... R24D (Refer to EIAJ (Electronic Industries Association of Japan)) Relays per reel: 1,000 Direction of Relay Insertion Carrier tape Reel Dimensions A Carrier Tape Dimensions G6L-1F 4 ±0.1 2 ±0.1 12 ±0.1 G6L Pulling Direction Orientation mark Top tape (cover tape) Pulling direction Embossed tape 25.5 ±0.5 29.5 ±1 13 dia. ...
Page 7
... UL approval: UL60950 (File No. E41515) CSA approval: C22.2 No.60950 (File No. LR31928) Contact form Coil rating SPST-NO G6L-1P and G6L-1F VDC VDC • The thickness of cream solder to be applied should be within a range between 150 and 200 µ OMRON's recommended PCB pattern. Correct Soldering PCB Visually check that the Relay is properly soldered ...
Page 8
... Relay may not function at its full performance level. Therefore, always use an instantaneous ON and instantaneous OFF when applying the voltage. Be sure that the rated voltage or zero voltage is reached within 1 ms. G6L the heat-resisting ...