HF12-1A54-8 MEDER electronic, HF12-1A54-8 Datasheet

RELAY REED SPST-NO 12V 1.5A 25W

HF12-1A54-8

Manufacturer Part Number
HF12-1A54-8
Description
RELAY REED SPST-NO 12V 1.5A 25W
Manufacturer
MEDER electronic
Series
HFr
Datasheets

Specifications of HF12-1A54-8

Relay Type
RF
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
1.5A @ 500VAC/DC
Coil Type
Standard
Coil Current
47.9mA
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.8 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form A
Maximum Switched Power
25 W
Maximum Switched Current
1.5 A
Coil Suppression Diode
No
Coil Resistance
250 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
HF121A54-8
HF121A54-8
Q1860636
High Frequency and
High Power Reed Relays
160
HF Series
Options
Series
HF
Radio frequency technology
Antenna tuning units
Transmit / receive requirements
05, 12, 24
Nominal
Voltage
APPLICATIONS
XX -
Contact
Form
A, B
XX
ORDER INFORMATION
Switch
Model
54 -
All dimensions in mm [inch]
www.meder.com
DIMENSIONS
5, 6, 7, 8, 9
Pin Out
X
High voltage RF Reed Relays use a patented coil
encapsulation, external electrostatic shields, and
magnetic shields. For this series we use a special
copper-plated Form A switch with a breakdown
voltage up to 10 kVDC. The contacts are suitable
for carrying current up to 3 Amps (5 Amps available)
at 30MHz.
contacts are available)
Normally open contacts (Normally closed
5 Amps available
Part Number Example
HF05 - 1A54 - 6
05 is the nominal voltage
1A is the contact form
54 is the switch model
6 is the breakdown voltage (6 kVDC)
DESCRIPTION
MEDER electronic
FEATURES

Related parts for HF12-1A54-8

HF12-1A54-8 Summary of contents