TF2-12V Panasonic Electric Works, TF2-12V Datasheet - Page 3

no-image

TF2-12V

Manufacturer Part Number
TF2-12V
Description
RELAY DPDT 1A 12VDC PC MNT
Manufacturer
Panasonic Electric Works
Series
TFr
Datasheet

Specifications of TF2-12V

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Standard
Coil Current
6.7mA
Coil Voltage
12VDC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1017
255-1017-5
255-1017
TF2E-12V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TF2-12V
Manufacturer:
Panasonic
Quantity:
12 000
Part Number:
TF2-12VDC
Manufacturer:
TaiRO
Quantity:
5 400
TF
REFERENCE DATA
1. Maximum switching capacity
4.-(1) Electrical life (DC load)
Tested sample: TF2-12V, 6 pcs.
Condition: 1 A 30 V DC resistive load, 20 cpm
Change of pick-up and drop-out voltage
Change of contact resistance
7. Set/reset time characteristics
Tested sample: TF2-L2-12V, 5 pcs.
3
100
100
1.0
0.5
0.4
0.3
0.2
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
6
5
4
3
2
1
0
0
0
80
5
Pick-up voltage
Coil applied voltage, %V
Drop-out voltage
30
90
No. of operations, ×10
No. of operations, ×10
Switching voltage,V
100
10
5
DC load (cosϕ=1)
AC load (cosϕ=1)
110
100
Set time
Reset time
15
120
200
Max.
Min.
4
4
20
10
Max.
Min.
Max.
Min.
Max.
Min.
2. Life curve
Change of contact resistance
5. Coil temperature rise
Tested sample: TF2-xxV
Measured portion: Inside the coil
Ambient temperature: 30°C
8. Distribution of pick-up and drop-out voltage
Tested sample: TF2-12V, 50 pcs.
100
100
70
60
50
40
30
20
10
20
90
80
70
60
50
40
30
20
10
30
10
10
0
0
0
0
Drop-out
10
voltage
100 110 120 130
Nominal coil voltage
Ratio against the rated voltage, %V
20 30 40 50 60 70 80 90 100
Coil applied voltage, %V
5
0.5
3-12 V DC
24 V DC
48 V DC
No. of operations, ×10
30 V DC resistive load
125 V AC resistive load
Switching current, A
86°F
10
Pick-up
voltage
1.0
140
15
1 A
150
1 A
1 A
0 A
4
20
Max.
Min.
3. Mechanical life
Tested sample: TF2-12V, 10 pcs.
4.-(2) Electrical life (AC load)
Tested sample: TF2-12V, 6 pcs
Condition: 0.5 A 125 V AC resistive load, 20 cpm
Change of pick-up and drop-out voltage
6. Operate/release time characteristics
Tested sample: TF2-12V, 5 pcs.
9. Distribution of set and reset voltage
Tested sample: TF2-L2-12V, 20 pcs.
100
100
90
80
70
60
50
40
30
20
10
90
80
70
60
50
40
30
20
10
10
6
5
4
3
2
1
0
5
0
0
0
10
80
20
Release time
Set voltage
Reset voltage
Ratio against the rated voltage, %V
10
30 40 50 60 70 80 90 100
Coil applied voltage, %V
Pick-up voltage
Drop-out voltage
90
Pick-up voltage
Drop-out voltage
No. of operations, ×10
No. of operations, ×10
Operate time
100
100
5
110
1,000
120
4
4
Max.
Min.
Max.
Min.
10,000
Max.
Min.
Max.
Min.
10
Max.
Min.
Max.
Min.

Related parts for TF2-12V