AQW654 Panasonic Electric Works, AQW654 Datasheet - Page 2

RELAY OPTO AC/DC 400V 120MA 8DIP

AQW654

Manufacturer Part Number
AQW654
Description
RELAY OPTO AC/DC 400V 120MA 8DIP
Manufacturer
Panasonic Electric Works
Series
PhotoMOS™ AQWr
Datasheets

Specifications of AQW654

Circuit
DPST-NO/NC (1 Form A and B)
Output Type
AC, DC
On-state Resistance
16 Ohm
Load Current
120mA
Voltage - Input
1.14VDC
Voltage - Load
0 ~ 400 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
8-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2960
AQW654

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AQW654
Quantity:
5 510
Part Number:
AQW654A
Manufacturer:
Panasonic Electric Works
Quantity:
135
HE Form A & B (AQW654)
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
*Operate/Reverse time
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper relay operation and resetting.
■ For Dimensions.
■ For Schematic and Wiring Diagrams.
■ For Cautions for Use.
■ These products are not designed for automotive use.
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
When using 2 channels
Input
Output
Transfer
characteristics
Output
If you are considering to use these products for automotive applications, please contact your local Panasonic Electric
Works technical representative.
For more information.
Input
Input LED current
250
200
150
100
50
0
–40
Item
Ton
–20
LED operate current
LED reverse current
LED dropout voltage
On resistance
Off state leakage current
Operate time*
Reverse time*
I/O capacitance
Initial I/O isolation resistance
0
Ambient temperature, °C
20
1) N.O.
Item
40
–40°F to +185°F
60
Symbol
8085 100
I
F
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Toff
Typical
Maximum
Minimum
Typical
Typical
Maximum
Typical
Maximum
Maximum
Typical
Maximum
Typical
Maximum
Typical
Maximum
Minimum
90%
10%
2. On resistance vs. ambient temperature
characteristics
Measured portion: between terminals 5 and 6,
7 and 8; LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 120 mA (DC)
Recommended value
Output
Input
I
I
I
I
T
T
T
T
20
18
16
14
12
10
Fon
Foff
Foff
Fon
Symbol
8
6
4
2
0
on
off
off
on
5
–40
I
C
R
R
(N.O.)
(N.O.)
(N.O.)
(N.C.)
(N.O.)
(N.C.)
(N.C.)
(N.C.)
V
Leak
on
iso
iso
F
–20
Toff
Across terminals 5 and 6 (N.O.)
Across terminals 7 and 8 (N.C.)
Ambient temperature, °C
0
20
2) N.C.
0.04 ms (N.O.) 0.36 ms (N.C.)
0.8 ms (N.O.) 1.2 ms (N.C.)
40
1.25 V (1.14 V at I
Unit
mA
60
AQW654(A)
1,000 MΩ
0.9 mA
0.4 mA
0.8 mA
8085
0.8 pF
1.5 pF
3 mA
1.5 V
11 Ω
16 Ω
1 µA
2 ms
1 ms
F
Ton
= 5 mA)
3. Operate time vs. ambient temperature
characteristics
LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 120 mA (DC)
10%
90%
4
3
2
1
0
–40
I
I
I
I
I
Within 1 s on time
I
I
V
I
I
I
I
f = 1 MHz
V
500 V DC
L
L
F
F
L
F
F
F
L
F
L
–20
L
B
= Max.
= Max.
= 50 mA
= 5 mA (N.O.) I
= Max.
= 0 mA (N.O.)
= 5 mA (N.C.)
= 0 mA ➝ 5 mA
= Max.
= 5 mA ➝ 0 mA
= Max.
= Max.
= 0 V
Across terminals 5 and 6 (N.O.)
Across terminals 7 and 8 (N.C.)
Ambient temperature, °C
0
20
Remarks
F
40
= 0 mA (N.C.)
60
8085

Related parts for AQW654