CX380D5R Crydom Co., CX380D5R Datasheet

RELAY SSR 5A 380VAC AC OUT SIP

CX380D5R

Manufacturer Part Number
CX380D5R
Description
RELAY SSR 5A 380VAC AC OUT SIP
Manufacturer
Crydom Co.
Series
CXr
Datasheets

Specifications of CX380D5R

Load Current
5A
Circuit
SPST-NO (1 Form A)
Output Type
AC
Voltage - Input
4 ~ 15VDC
Voltage - Load
48 ~ 530 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
4-SIP
Control Voltage Type
DC
Input Voltage
4VDC To 15VDC
Load Voltage Range
48Vrms To 530Vrms
Switching Mode
Random
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
CSA, VDE
Approval Category
UL
Contact Configuration
SPST-NO
Relay Terminals
Through Hole
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CC1597
CX380D5R

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CX380D5R
Manufacturer:
Crydom Co.
Quantity:
135
OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Maximum I
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS 1
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ Nominal Voltage
G E N E R A L N O T E S
1
2
3
SERIES CX.
Rev. 061009
PAGE 1 OF 3
All parameters at 25ºC unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models).
2
t for Fusing, (8.3 msec.) [A
M O D E L N U M B E R S
3
M O D E L N U M B E R S
N o m i n a l Vo l t a g e
2
sec]
AC CONTROL
DC CONTROL
2
• SCR Output
• Ultra High Surge Rating
• Crydom’s Patented Design
Crydom's family of SPST-NO relays
achieves the highest power switching
capability in a PC-mounted air-cooled
package. Advanced features include
CX240D5
3-15 Vdc
300 Ohm
15 mAdc
3.0 Vdc
1.0 Vdc
5 V d c
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
(120Vac)
(24Vdc)
(24Vac)
(5Vdc)
DC CONTROL
CX380D5
CX480D5
240 Ohm
15 mAdc
4-15 Vdc
4.0 Vdc
1.0 Vdc
5 V d c
CXE240A5
CXE240D5
CX240A5
CX240D5
12-280
.06-5
600
250
260
500
1.4
0.1
0.5
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
5 Amp • 120/240, 380, 480 Vac • AC OUTPUT SIP
CXE240D5
CXE380D5
CXE480D5
1500 Ohm
15-32 Vdc
15.0 Vdc
15 mAdc
2 4 V d c
1.0 Vdc
© 2007 CRYDOM Inc., Specifications subject to change without notice.
exceptional steady state current, plus
ultra-high surge ratings. Models are
available to switch up to 660 Vrms with
AC or DC control, and either zero-cross
or random turn-on ("R") switching ver-
sions. Pinout is compatible with Series
6 and OAC type I/O modules.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
CXE380D5
CX380D5
48-530
.06-5
1200
250
260
500
1.4
0.1
0.5
90-140 Vrms
14.1k Ohm
10 mArms
90.0 Vrms
10.0 Vrms
CX240A5
1 2 0 Va c
Series
AC CONTROL
CXE480D5
CX480D5
48-660
.06-5
1200
250
260
500
1.4
0.1
0.5
18-36 Vrms
CXE240A5
10 mArms
18.0 Vrms
2.1k Ohm
2.0 Vrms
2 4 Va c
CX

Related parts for CX380D5R

CX380D5R Summary of contents

Page 1

... PAGE Amp • 120/240, 380, 480 Vac • AC OUTPUT SIP • SCR Output • Ultra High Surge Rating • Crydom’s Patented Design Crydom's family of SPST-NO relays achieves the highest power switching capability in a PC-mounted air-cooled package. Advanced features include AC CONTROL ...

Page 2

6.0 5.0 4.0 3.0 2.0 1 AMBIENT TEMPERATURE [°C] Max. Load Current vs. Temp. AVAILABLE OPTIONS ...

Page 3

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO HAZARD OF RIESGO DE ELECTRIC DESCARGA SHOCK, ELECTRICA O EXPLOSION, EXPLOSION. OR ARC FLASH. • Desconectar • Disconnect all todos los power before suministros de installing or energia a este ...

Page 4

ANNEX – ENVIRONMENTAL INFORMATION: The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. ...