G3NA-290B-UTU AC100-240 Omron, G3NA-290B-UTU AC100-240 Datasheet - Page 6

RELAY SSR 90A@240VAC 120VAC IN

G3NA-290B-UTU AC100-240

Manufacturer Part Number
G3NA-290B-UTU AC100-240
Description
RELAY SSR 90A@240VAC 120VAC IN
Manufacturer
Omron
Series
G3NAr
Datasheets

Specifications of G3NA-290B-UTU AC100-240

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
90A
Voltage - Input
100 ~ 240VAC
Voltage - Load
19 ~ 264 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
100 VAC to 240 VAC
Load Current Rating
90 A
Contact Form
1 Form A
Relay Type
General Purpose Hockey Puck
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NA290BUTUAC100240
Z2069
One Cycle Surge Current
The values shown by the solid line are for non-repetitive inrush currents.
Keep the inrush current below the values shown by the dotted line if it occurs repetitively.
Thermal Resistance Rth
(Back of Junction SSR) (Examples)
456
Temperature
Characteristics (for
Must Operate Voltage
and Must Release
Voltage)
G3NA-205B
G3NA-210B
G3NA-220B
G3NA-240B
G3NA-275B-UTU
G3NA-475B-UTU
G3NA-290B-UTU
G3NA-490B-UTU
G3NA-D210B
−20
−40
60
40
20
30
28
26
24
22
20
18
16
14
12
10
40
20
0
8
6
4
2
0
0
−30
G3NA-205B
10
G3NA-D210B
10
G3NA-2❏❏B AC input
20
−20
30
30
50 70
50
0
100
100
Model
Solid State Relay
200 300
Ambient temperature (°C)
20
200
Energized time (ms)
Energized time (ms)
500
500
40
1,000
60
1,000
80
5,000
2,000
100
Heat Sink Area vs.
Load Current
G3NA
150
100
3,000
2,000
1,000
50
900
800
700
600
500
400
300
200
100
0
700
500
300
200
100
10
0
70
50
30
20
G3NA-210B
G3NA-410B
G3NA-275B-UTU
G3NA-475B-UTU
10
0
G3NA-220B
Ambient
temperature 80°C
2
30
Rth (°C/W)
4
50
30
6
3.22
2.62
1.99
0.45
0.45
2.62
100
8
50
10
200
12
100
Energized time (ms)
500
Energized time (ms)
14
Ambient
temperature 40°C
Aluminum plate
3.2 mm thick
16
1,000
Load current (A)
18
300
20
22
5,000
1,000
24
1,200
1,000
200
150
100
50
800
600
400
200
Note: The heat sink area refers to the combined area
0
Thermal Resistance Rth of Heat Sinks
(Examples)
Note: When using a commercially available heat sink, use one with a
10
Y92B-N50
Y92B-N100
Y92B-N150
Y92B-A100
Y92B-A150N
Y92B-A250
Y92B-P250NF
0
G3NA-220B
G3NA-420B
G3NA-290B-UTU
G3NA-490B-UTU
10
30
of the sides of the heat sink that radiate heat.
For example, when a current of 18 A is allowed
to flow through the SSR at 40°C, the graph
shows that the heat sink area is about 450 cm
Therefore, if the heat sink is square, one side of
the heat sink must be 15 cm (
longer.
thermal resistance equal to or less that the OMRON Heat Sink.
50
30
100
50
200
Model
100
500
Energized time (ms)
Energized time (ms)
1,000
300
5,000
1,000
400
300
200
100
0
10
G3NA-240B
G3NA-440B/-450B
450 (cm
30
50
100
2
Rth (°C/W)
)/2
200
1.63
1.38
1.63
1.37
1.00
0.46
) or
2.8
2
500
Energized time (ms)
.
1,000
5,000

Related parts for G3NA-290B-UTU AC100-240