G3JA-D409B AC/DC24 Omron, G3JA-D409B AC/DC24 Datasheet - Page 10

no-image

G3JA-D409B AC/DC24

Manufacturer Part Number
G3JA-D409B AC/DC24
Description
STARTER 3PHASE HYBRD 200-480V 9A
Manufacturer
Omron
Series
G3JAr
Datasheet

Specifications of G3JA-D409B AC/DC24

Circuit
3PST (3 Form A)
Output Type
AC
Load Current
9A
Voltage - Input
24VAC/DC
Voltage - Load
200 ~ 480 V
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3JA-D409BAC/DC24
G3JAD409BACDC24
Nomenclature
■ Part Names and Functions
Upgraded Models
Production of a new version of the Soft Starter (version 2) with
added functions was started in August 2008. The DIP switch
settings of the new version are different from the previous version.
For details, refer to Upgrades for Version 2 on page 13.
Auxiliary Contacts
The G3JA-C is equipped with two auxiliary contacts as a
standard feature. One contact can be used for fault detection
output. The other one is used to output operating status and
can be set to either Normal or Up-to-speed using the DIP
switch setting at pin number 14.
An optional Auxiliary Contact Block can be added, and DIP
switch pin number 14 can be used to set the operating status to
output (either Normal or Set Speed).
Reset Button
All faults can be reset by pressing the Reset Button or turning
OFF the control power supply. Cooling time may be required
before overload and overtemperature status can be reset.
Note: Test Mode for overload testing will be entered when the
Control Terminals
The G3JA-C has eight input terminals on the front. Each
terminal is described in the following table.
Terminal
A1
A2
IN1
IN2
97
98
13
14
Reset Button is pressed for approximately seconds.
Test Mode will be cancelled when the Reset Button is
pressed again.
Control power supply input
Control power supply common
START input
STOP input
NO auxiliary contact (auxiliary contact for fault detection output)
NO auxiliary contact (auxiliary contact for fault detection output)
NO auxiliary contact (normal/up-to-speed)
NO auxiliary contact (normal/up-to-speed)
Description
Main Circuit Terminals,
Power Supply Side
Main Circuit Terminals,
Load Side
G3JA-C
SOFT STARTER
Ver.2
Note: The indicator will flash seven times in test mode (trip test).
Overload FLA Setting Dial
Use this dial to set the trip current to the rated full-load
current of the motor.
be possible to drive the motor properly.
For a 3-phase, 6-wire motor, use the following formula
to calculate the dial setting.
Set value = Total motor load current/1.73
For example, if the total motor load current is 20 A, the
dial setting is 11.6 A (20 A/1.73).
RUN/FAULT Indicator
The G3JA-C monitors the status before startup and
during operation. One indicator indicates both normal
operation (RUN) and faults (FAULT). If the G3JA-C
detects a fault, it turns OFF the motor and indicates
the fault with a flashing LED indicator.
The G3JA-C monitors the following conditions.
DIP Switch Configuration
Use the DIP switch to set the functions.
Overload
Over-
temperature
Phase loss
Current
imbalance
Shorted
SCR
Phase
reversal
DIP switch
pin
Fault
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
Auxiliary/optional auxiliary contact (normal/up-to-speed)
Start time
Start mode (current limit start or soft start)
Soft stop
Long time setting for start time
Kick start
Overload class selection
Overload reset
Motor wiring (Line or Delta)
Phase reversal protection
Current limit start setting (when selected) or initial
torque setting for a soft start (when selected)
If the setting is not correct, it will not
Flashing indicator status
Function
G3JA-C
10