AQZ105D Panasonic Electric Works, AQZ105D Datasheet
AQZ105D
Specifications of AQZ105D
Available stocks
Related parts for AQZ105D
AQZ105D Summary of contents
Page 1
... The AC/DC dual type is capable of bi- directional control, and unlike conventional SSRs, does not have to be used differently depending on the load. The DC-only type is well suited for control of DC solenoids and DC motors. Package Part No. AQZ102D AQZ105D SIL4-pin AQZ107D AQZ104D Package Part No. AQZ202D AQZ205D SIL4-pin ...
Page 2
... T –40°C to +75°C –40°F to +167°F opr –40°C to +60°C –40°F to +140°F T –40°C to +100°C stg Symbol AQZ102D AQZ105D Typical V Fon Maximum Minimum V Foff Typical Typical I IN 0.033 Ω ...
Page 3
... IN 80 15V<V 30V –40 – 100 Ambient temperature, °C All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 1 Form A Voltage-sensitive (AQZ10❍D, 20❍D) Symbol AQZ202D AQZ205D Typical V Fon Maximum Minimum V Foff Typical Typical I IN 0.066 Ω 0.180 Ω Typical R on 0.18 Ω ...
Page 4
... Ambient temperature, °C 3.-(1) On resistance vs. ambient temperature characteristics (DC type) Input voltage Continuous load current: 3.6 A (DC) (AQZ102D) 2.3 A (DC) (AQZ105D) 0.25 0.20 0.15 AQZ105D 0.10 0.05 AQZ102D 0 –40 – Ambient temperature, °C 3.-(4) On resistance vs. ambient temperature characteristics (AC/DC type) Input voltage ...
Page 5
... AQZ105D,205D AQZ102D,202D – 100 Load voltage, V 13.-(1) Output capacitance vs. applied voltage characteristics (DC type) Frequency: 1 MHz; Ambient temperature: 25°C 77°F 2000 1800 1600 1400 1200 AQZ102D 1000 800 AQZ105D 600 AQZ107D 400 AQZ104D 200 100 Applied voltage, V ACCESSORY (mm inch) Socket ±0.6 22.6 ± ...