LCA210STR Clare, LCA210STR Datasheet

RELAY OPTOMOS 85MA DP-NO 8SMD

LCA210STR

Manufacturer Part Number
LCA210STR
Description
RELAY OPTOMOS 85MA DP-NO 8SMD
Manufacturer
Clare
Series
LCA, OptoMOS®r
Datasheets

Specifications of LCA210STR

Circuit
DPST (2 Form A)
Output Type
AC, DC
On-state Resistance
35 Ohm
Load Current
85mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 350 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
8-SMD (300 mil)
Load Voltage Rating
350 V
Load Current Rating
85 mA
Mounting Style
SMD/SMT
Relay Type
Common
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
Applications
DS-LCA210-R7
Load Voltage
Load Current
Max R
Small 8 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Surface Mount and Tape & Reel Versions Available
Telecom Switching
Instrumentation
Security
Aerospace
Industrial Controls
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment-Patient/Equipment Isolation
ON
RMS
Input/Output Isolation
LCA210
350
85
35
Units
mA
V
www.clare.com
Description
The LCA210 is a common input 1-Form 2A solid state relay
which has two independent optically couple MOSFETS
controlled by a common input signal. The efficient MOS-
FET switches and photovoltaic die use Clare’s patented
OptoMOS
output isolation. The optically coupled input is controlled by
highly efficient GaAIAs infrared LEDs. Common input
OptoMOS relays can replace standard dual pole relays in
a variety of applications. The common input relay elimi-
nates the need to make an external circuit connection
when both poles are controlled by a common signal.
Approvals
Pin Configuration
Ordering Information
Part #
LCA210
LCA210S
LCA210STR
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
®
architecture to provide 3750 V
LCA210 Pinout
Normally Open (Form A) Devices
Description
8 Pin DIP (50/Tube)
8 Pin Surface Mount (50/Tube)
8 Pin Surface Mount (1000/Reel)
Switching Charcteristics of
Dual Pole OptoMOS® Relays
RMS
LCA210
of input to
1

Related parts for LCA210STR

LCA210STR Summary of contents

Page 1

... BS EN 60950:1992 (BS7002:1992) • Certificate #: 7344 BS EN 41003:1993 • Certificate #: 7344 Ordering Information Part # Description LCA210 8 Pin DIP (50/Tube) LCA210S 8 Pin Surface Mount (50/Tube) LCA210STR 8 Pin Surface Mount (1000/Reel) Pin Configuration LCA210 Pinout Switching Charcteristics of Normally Open (Form A) Devices www.clare.com LCA210 of input to RMS 1 ...

Page 2

... Conditions Symbol Min - 10ms max I - LPK I =85mA =350V LEAK =8mA, V =10V =8mA, V =10V OFF 50V; f=1MHz C - OUT I =120mA 0.8 I =8mA 3750 I/O www.clare.com Typ Max Units - 350 170 µ 100 mA 1 1.2 1 µ RMS Rev. 7 ...

Page 3

... Switch Dropout F (N=50 Ambient Temperature = (Load Current = 85mADC LED Current (mA) LCA210 Typical Load Current vs. Temperature Temperature ( C) LCA210 Typical Turn-On vs. Temperature (Load Current = 40mADC) 8mA 16mA 32mA 100 Temperature ( C) www.clare.com LCA210 LCA210 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 420 425 430 435 ...

Page 4

... Time www.clare.com LCA210 Typical Turn-Off vs. LED Forward Current (Load Current = 50mADC) LED Forward Current (mA) LCA210 Typical I for Switch Dropout F vs. Temperature (Load Current = 50mADC) Temperature ( C) Rev. 7 ...

Page 5

... MAX. (.016) 7.493 .102 (.295 .004) 4.877 (.192) .050R TYP. 11.989 .102 Tape (.472 .004) User Direction of Feed www.clare.com PC Board Pattern (Top View) 2.540 .127 8-.800 DIA. (.100 .005) (8-.031 DIA.) 7.620 6.350 .127 (.300 .005) (.250 .005) 7.620 ...

Page 6

... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to sup- port or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice ...