RELAY OPTOMOS 170MA SP-NO 6-DIP

LCA127L

Manufacturer Part Number
LCA127L
Description
RELAY OPTOMOS 170MA SP-NO 6-DIP
Manufacturer
Clare
Series
LCA, OptoMOS®r
Datasheet

Specifications of LCA127L

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
15 Ohm
Load Current
170mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 250 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
6-DIP (0.300", 7.62mm)
Input Type
DC
Input Voltage (max)
1.4V
Output Voltage (max)
250V
Input Current (max)
50mA
Output Current
170mA
Isolation Voltage
3750(RMS)V
Circuit Arrangement
1 Form A
Package Type
PDIP
Output Device
MOSFET
Pin Count
8
Mounting
Through Hole
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Load Voltage Rating
250 V
Load Current Rating
170 mA
Relay Type
Single Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCA127L
Quantity:
23
Part Number:
LCA127L
Manufacturer:
CPClare
Quantity:
4 640
1
Absolute Maximum Ratings @ 25ºC
1
2
Electrical Characteristics @ 25ºC
2
Parameter
Output Characteristics
Load Current, Continuous
Load Current Limiting
On-Resistance
Off-State Leakage Current
Switching Speeds
Output Capacitance
Input Characteristics
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance, Input to Output
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Input Power Dissipation
Total Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Measurement taken within 1 second of on-time.
Turn-On
Turn-Off
Derate Linearly 1.33 mW / ºC
Derate Linearly 6.67 mW / ºC
AC/DC Confi guration
DC Confi guration
AC/DC Confi guration
DC Confi guration
Peak (10ms)
1
2
1
-40 to +125
Ratings
-40 to +85
3750
250
150
800
50
5
1
I
F
V
Conditions
= 5mA, V
L
=50V, f=1MHz
I
I
I
V
L
I
L
L
V
F
=200mA
=200mA
L
= 200mA
=250V
R
= 5mA
Units
= 5V
-
-
-
-
-
mW
mW
V
mA
V
°C
°C
V
A
rms
L
P
www.clare.com
= 10V
P
Symbol
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
C
I
R
C
LEAK
I
t
t
V
I
OUT
I
I
I
CL
ON
on
off
R
I/O
L
F
F
F
Min
190
0.4
0.9
-
-
-
-
-
-
-
-
-
-
-
Typ
235
0.7
1.2
13
50
5
3
-
-
-
-
-
-
-
Max
170
250
280
1.4
15
10
6
1
5
5
5
-
-
-
LCA127L
Units
mA
mA
mA
mA
ms
ms
µA
pF
µA
pF
Ω
V
R03