H3JA-8C AC100-120 10S Omron, H3JA-8C AC100-120 10S Datasheet - Page 3

RELAY TIMER DPDT 1-10SEC 120VAC

H3JA-8C AC100-120 10S

Manufacturer Part Number
H3JA-8C AC100-120 10S
Description
RELAY TIMER DPDT 1-10SEC 120VAC
Manufacturer
Omron
Series
H3JAr
Datasheet

Specifications of H3JA-8C AC100-120 10S

Relay Type
Integrated
Function
On-Delay
Circuit
DPDT (2 Form C)
Delay Time
1 Sec ~ 10 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 120VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Output Current
5A
Supply Voltage Max
120VAC
Time Range Max
10s
Switch Function
DPDT
Time Range Min
1s
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
H3JA8CAC10012010S
Z1646
■ Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Approved standard
Case color
Degree of protection
Weight
±2% max.
±7% max.
±2% max.
±5% max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and between
contact-carrying and control circuit, and between contacts of different poles)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±1.5 kV (between power terminals) and ±1.5 kV (between output terminals), square-wave noise by
noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 8 kV
Malfunction: 6 kV
Destruction: 10 to 55 Hz with 0.75-mm double amplitude in 3 directions for 1 hour each.
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude in 3 directions for 10 minutes each.
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating: –10°C to 55°C
Storage: –25°C to 65°C
Operating: 35% to 85%
H3JA-8A
Mechanical: 10,000,000 operations min.
Electrical: 60,000 operations min. (7 A resistive load at 250 VAC, 360 operations/h)
H3JA-8C
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (5 A resistive load at 250 VAC, 360 operations/h)
(EMI)
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS)
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
Immunity RF-interference from AM Radio Waves:
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
UL508, CSA C22.2 No. 14, conforms to EN61812-1
Light gray (Munsell 5Y7/1)
IP40 (panel surface)
H3JA-8A: Approx. 50 g
H3JA-8C: Approx. 60 g
8 kV air discharge (level 3)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)