H3CR-A AC100-240/DC100-125 Omron, H3CR-A AC100-240/DC100-125 Datasheet - Page 4

RELAY TIMER DPDT ANALOG 120\240V

H3CR-A AC100-240/DC100-125

Manufacturer Part Number
H3CR-A AC100-240/DC100-125
Description
RELAY TIMER DPDT ANALOG 120\240V
Manufacturer
Omron
Series
H3CR-Ar

Specifications of H3CR-A AC100-240/DC100-125

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 240VAC
Voltage - Supply
100 ~ 240VAC, 100 ~ 125VDC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Time Range
0.05 Sec. To 300 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
6
Body Material
95B5375
No. Of Pins
11
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A AC100-240/DC100-125Q
H3CR-A-AC100-240
H3CR-A-AC100-240 DC1
H3CR-A-AC100-240 DC100-125
H3CRAAC100240DC100125
H3CRAAC100240DC100125Q
Z876
Specifications
■ General
*The internal circuits are optically isolated from the output. This enables universal application as NPN or PNP transistor.
■ Time Ranges
Note: When the time setting knob is turned below “0” until the point where the time setting knob stops, the output will operate instantaneously at
Standard (0.05-s to 300-h) Models
Double (0.1-s to 600-h) Models
Operating mode
Pin type
Input type
Time-limit output type
Instantaneous output type ---
Mounting method
Approved standards
Full scale
setting
Full scale
setting
all time range settings.
Time unit
Time unit
Item
1.2
3
12
30
2.4
6
24
60
0.05 to 1.2
0.3 to 3
1.2 to 12
3 to 30
0.1 to 2.4
0.6 to 6
2.4 to 24
6 to 60
A: ON-delay
B: Flicker OFF start
B2: Flicker ON start
C: Signal ON/OFF-delay
D: Signal OFF-delay
E: Interval
G: Signal ON/OFF-delay (Only for H3CR-A-300)
J: One-shot (Only for H3CR-A-300)
11-pin
No-voltage input
H3CR-A/-A8/-AP: Relay output (DPDT)
H3CR-AS/-A8S: Transistor output (NPN/PNP universal)*
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1 for Timers with Contact Outputs.
Output category according to EN60947-5-2 for Timers with Transistor Outputs.
H3CR-A/-AS
s (sec)
s (sec)
0.12 to 1.2
0.24 to 2.4
Voltage input
min (min)
min (min)
H3CR-AP
A: ON-delay (power supply start)
B2: Flicker ON start (power supply start)
E: Interval (power supply start)
J: One-shot (power supply start)
8-pin
---
H3CR-A8/-A8S
h (hrs)
h (hrs)
1.2 to 12
3 to 30
12 to 120
30 to 300
2.4 to 24
6 to 60
24 to 240
60 to 600
Relay output (SPDT)
Relay output (SPDT)
×10 h (10 hrs)
×10 h (10 hrs)
H3CR-A8E
H3CR-A
4

Related parts for H3CR-A AC100-240/DC100-125