H3CR-A AC24-48/DC12-48 Omron, H3CR-A AC24-48/DC12-48 Datasheet - Page 15

RELAY TIMER ANALOG 24VDC/AC

H3CR-A AC24-48/DC12-48

Manufacturer Part Number
H3CR-A AC24-48/DC12-48
Description
RELAY TIMER ANALOG 24VDC/AC
Manufacturer
Omron
Series
H3CR-Ar

Specifications of H3CR-A AC24-48/DC12-48

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 240VAC
Voltage - Supply
24 ~ 48VAC, 12 ~ 48VDC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Time Range
0.05 Sec. To 300 Hr.
Supply Voltage Ac, Min
24VAC
No. Of Timing Functions
6
Body Material
93B4352
No. Of Pins
11
Supply Voltage Ac, Max
48VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A-AC/DC24
H3CRAAC24-48/DC12-48
H3CRAAC2448DC1248
Z997
H3CR-A8E
Note: 1. The minimum power-opening time (“Rt”) is 0.1 s.
Nomenclature
Time range selector (select one
from 1.2, 3, 12, and 30 at full
scale; with the H3CR-A@-301,
select from 2.4, 6, 24, or 60 at
full scale.)
A:
ON-delay
B
Flicker ON
start
E:
Interval
J:
One-shot
output
Operating
2
:
mode
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
Output indicator (orange)
(Lit when output)
Output relay (NO)
(output indicator)
Instantaneous
output relay (NC)
Instantaneous
output relay (NO)
Output relay (NC)
Output relay (NO)
(output indicator)
Instantaneous
output relay (NO)
Output relay (NO)
(output indicator)
Instantaneous
output relay (NC)
Instantaneous
output relay (NO)
Instantaneous
output relay (NC)
Power indicator
Instantaneous
output relay (NC)
Output relay (NC)
Instantaneous
output relay (NO)
Output relay (NC)
Output relay (NO)
(output indicator)
Output relay (NC)
Power indicator
Power indicator
Power indicator
Power
Power
Power
Power
Power indicator (green) (Flashes when Timer
operates; lit when Timer stops operating)
(Fixed)
Time setting
knob (set time)
Timing chart
Operating mode display window
Operating mode selector
Select a mode from:
A, B, B2, C, D, and E (H3CR-A, -AP, and -AS) A,
Scale range display windows
Time unit display window
Time unit selector (select one
from sec, min, hrs, and 10h)
(Fixed)
B2, E and J (H3CR-A8, -A8S, and -A8E) G
and J (H3CR-A-300)
Power
Output
Basic operation
Power
Output
Power
Output
Basic operation
Basic operation
Power
Output
Basic operation
t
t
t
t
t
t
H3CR-A
1±0.6 s
(Fixed)
t
15