H3CR-F AC100-240 Omron, H3CR-F AC100-240 Datasheet - Page 11

RELAY REPEAT CYCLE ANLG 30HRS

H3CR-F AC100-240

Manufacturer Part Number
H3CR-F AC100-240
Description
RELAY REPEAT CYCLE ANLG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Datasheets

Specifications of H3CR-F AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 s to 30 Hrs
Supply Voltage
100 V to 240 V
Time Range
0.05 Sec. To 30 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
2
Body Material
38B610
No. Of Pins
11
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F-AC100-240
H3CR-F-AC100-240
H3CRFAC100240
Q2238220
Z2366
■ I/O Functions
■ Terminal Arrangement
Operation
■ Timing Chart
Nomenclature
H3CR-G8L
Inputs
Outputs
t1: Star operation time setting
t2: Star-delta transfer time
Note: Leave terminals 1, 3, and 4 open.
H3CR-G8L/-G8EL
Do not use them as relay terminals.
Model
http://www.ia.omron.com/
Control output
Star operation
indicator (green)
Delta operation
indicator (orange)
Scale range display
windows
Star operation time range selector
(select one from 6, 12, 60, and 120
at full scale)
Delta
operation
contact
---
If the time reaches the value set with the time setting knob, the star operation output will be turned OFF
and there will be delta operation output after the set star-delta transfer time has elapsed.
Power (2 − 7)
Instantaneous output
(1 − 3) (-E models)
Star operation
output (8 − 5)
Delta operation
output (8 − 6)
Star operation indicator
Delta operation indicator
Star
operation
contact
Instantaneous contact
Star-delta transfer time display window
H3CR-G8EL
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Lit
Not lit
Lit
Not lit
Timing chart
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Note: Leave terminal 4 open. Do not use
t1
them as relay terminals.
Time unit display
(sec is fixed)
Time setting knob (for setting
star operation time)
Star-delta transfer time selector
(select one from 0.05 s, 0.1 s,
0.25 s, and 0.5 s)
t2
Delta
operation
contact
Star
operation
contact
0.5 s min.
H3CR-G
11

Related parts for H3CR-F AC100-240