LD4T06P0 Red Lion Controls, LD4T06P0 Datasheet - Page 10

TIMER 6 DIGIT 4.0" 120VAC RED

LD4T06P0

Manufacturer Part Number
LD4T06P0
Description
TIMER 6 DIGIT 4.0" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Timerr
Datasheets

Specifications of LD4T06P0

No. Of Digits / Alpha
6
Digit Height
101mm
Power Consumption
26VA
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
4"
Ip/nema Rating
IP65 / NEMA 4X
Signal Output Type
Relay
Accuracy
±0.01% %
Connection Type
Wire Leads
Dimensions
26"L×2.25"W×7.875"H
Display Digit Height
4 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Material, Casing
Aluminum
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Supply Voltage Range
21.6V DC To 250V DC
Count Speed Max
10Hz
External Depth
57.15mm
External Length / Height
200mm
Rohs Compliant
Yes
Counter Supply Voltage
85-250VAC/11-16VDC
Display Font Color
Red
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
RLC125
can activate at a programmed Setpoint Value or can be set to activate when the
Timer starts (
the Setpoint is assigned to the Timer, the value is entered in the same display
format as the selected Timer Range.
On-Off Output mode (
determines when the Setpoint Output will deactivate. The output can be
programmed to deactivate at a Setpoint Off Value or can be set to deactivate
when the Timer starts (
entered. If the Setpoint is assigned to the Timer, the value is entered in the same
display format as the selected Timer Range.
Some parameters will not appear depending on the Setpoint Assignment and
Setpoint Output Action selected.
SPT ACTION DESCRIPTION




5.4 MODULE 4 - S



This parameter determines when the Setpoint output will activate. The output
Selecting
The Setpoint Off parameter only appears if the Setpoint Action is set to
Selecting
Module 4 is the programming module for the Setpoint Output parameters.
Select the display for Setpoint assignment.
This parameter selects the action of the Setpoint output as shown below.


PAR




Assignment
Setpoint



Latched Output Mode
Timed Output Mode
On-Off Output Mode




displays a sub-menu where the Setpoint Value is entered. If
SETPOINT OUTPUT ACTION
displays a sub-menu where the Setpoint Off Value is
) or stops (
SETPOINT ASSIGNMENT


Output Action
Setpoint




SETPOINT OFF





SETPOINT ON
) or stops (



). In this mode, the Setpoint OFF parameter

When Time or Count
When Time or Count
When Time or Count
= Setpoint On value
= Setpoint On value

OUTPUT ACTIVATES
Setpoint On value
to
).
to
Setpoint On




).
ETPOINT
Setpoint Off
OUTPUT DEACTIVATES
When Time or Count

(if
At Manual Reset
Output Time-Out
Setpoint Off value

After Setpoint
PARAMETER MENU
=

Time-out
O
Setpoint
Output
)
UTPUT
10

(
activated. This value is always entered in minutes, seconds, and hundredths of
seconds format. The maximum value is 99 minutes 59.99 seconds.
(
Start edge is applied on the Timer input.
Output activates (
not cause a display reset.



powered down.
output at power up. This parameter is not active when the Setpoint Action is
selected for timed output mode.
Assigned display resets. Reset can occur by the RST key or the User Input,
if programmed for that function. Select
reset when the display resets.



Stop Timer
This parameter is only active if the Setpoint Action is set to Timed Output mode
Stops the Timer when the Setpoint output activates (
The Timer Stop condition is cleared when a Timer Reset occurs, or a Time
Automatically resets the Setpoint Assigned display value when the Setpoint

Select
SETPOINT OUTPUT RESET WITH DISPLAY RESET
    
). Enter the time duration the Setpoint Output will remain ON once it is
). Select
P
will restore the output to the same state it was at before the meter was

ARAMETERS
SETPOINT OUTPUT POWER-UP STATE
to have the Setpoint Output deactivate (reset) when the Setpoint



Timer/Counter



Auto Reset

TIMER/COUNTER AUTO RESET
SETPOINT OUTPUT TIME-OUT
will activate the output at power up.
if the output should not affect the Timer Run/Stop status.
) or deactivates (
    



STOP TIMER


Output Reset
with Display
Setpoint



Reset


to
(

    



if the Setpoint output should not
). Select
Power-up
Setpoint
Output
State
)



if the output should
will deactivate the
) or deactivates