H3RN-21 AC24 Omron, H3RN-21 AC24 Datasheet
H3RN-21 AC24
Specifications of H3RN-21 AC24
H3RN21AC24
Related parts for H3RN-21 AC24
H3RN-21 AC24 Summary of contents
Page 1
... Ordering Information ■ List of Models Supply voltage 24 VAC; SPDT 12, 24 VDC DPST-NO Note: Specify both the model number and supply voltage when ordering. Example: H3RN-1 24 VAC Supply voltage ■ Accessories (Order Separately) Connecting Socket Timer H3RN-1/-11 H3RN-2/-21 http://www.ia.omron.com/ 2. Time Range None: Short-time range (0 ...
Page 2
... A at 250 VAC, resistive load (cosφ (G6B-2@14P-FD-US used) The minimum applicable load VDC (P reference value). Note: 1. When using the H3RN in any place where the ambient temperature is more than 50°C, supply 90% to 110% of the rated voltages (12 VDC: 95% to 110% of the rated voltage). ...
Page 3
... DIN Indication Timer circuit OUT PW Bottom View Pulse Operation A pulse output for a certain period can be obtained with a random external input signal. Use the H3RN in interval mode as shown in the following timing charts. H3RN-2/H3RN-21 Timer circuit External input !Caution Be careful when connecting wires. Mode ...
Page 4
... Time limit contact NO (4-3, 5-6) Run/Power indicator (PW) Output indicator (OUT) Power (1-8) Time limit contact NO (4-3, 5-6) Run/Power indicator (PW) Output indicator (OUT) Power (1-8) Time limit contact NO (4-3, 5-6) Run/Power indicator (PW) Output indicator (OUT) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3RN H3RN-2/H3RN-21 4 ...
Page 5
... DIP Switch Settings The 1-s range and ON-delay mode for H3RN-1/-2, 1-min range and ON-delay mode for H3RN-11/-21 are factory-set before shipping. Time Ranges Model Time range Time setting range H3RN- 0 H3RN min 0 min 10 min min H3RN-11, 1 min 0 min H3RN-21 ...
Page 6
... H3RN-1/H3RN-11 Front Mounting H3RN-2/H3RN-21 Front Mounting Mounting Height Use the P2RF-@-E or P2R-@7P to mount the H3RN. When ordering any one of these sockets, replace "@" with "05" for SPDT or "08" for DPST-NO. The P2RF-@ cannot be used because the hook is a different shape. ...
Page 7
... Do not use the H3RN in places where there is excessive dust, corro- sive gas, or direct sunlight. Make sure that there is a space more between any H3RN Models next to each other. (When using the P2RF-@-E Socket, a space more will be secured space more is not secured, the ambient temperature must be less than 50° ...
Page 8
... Timer uses half-wave rectification. Only a half AC wave is supplied to the proximity sensor, which may cause operation to be unstable.) Applicable Models H3Y, H3YN, H3RN, H3CA-8, RD2P, and H3CR(-A, -A8, -AP, -F, and -G) Countermeasure Wire through a relay and use the relay contacts to turn the power supply ON and OFF ...
Page 9
... T X • Be sure that only a qualified worker (e.g., an electrical engineer) performs electrical work for the Timer. Incandescent lamp load times the rated current Mercury light loads times the rated load (c)Copyright OMRON Corporation 2007 All Rights Reserved. T Auxiliary relay (e.g., MY Relays) ...
Page 10
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...