H3DE-M2 DC12 Omron, H3DE-M2 DC12 Datasheet - Page 5

no-image

H3DE-M2 DC12

Manufacturer Part Number
H3DE-M2 DC12
Description
RELAY TIMER ANALOG DIN 8MODE 12V
Manufacturer
Omron
Series
H3DEr
Datasheet

Specifications of H3DE-M2 DC12

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 120 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
H3DEM2DC12
Q2295545
Q2734960
Nomenclature
J H3DE-F
Front View
Bottom View
Output type selector switch for
H3DE-M2/-S2 (default setting
is time-limit output)
Operating mode selector
(select a mode from A, B, C,
B2, D, E, J, and G for the
H3DE-M1/-M2, from A, E, J,
and B2 for the H3DE-S1/S2)
Power-on indicator (green)
(Lit while the power is on.)
Output indicator (orange)
(Lit while Timer gives output.)
Time scale indicator
Time scale selector
(select 0.1 or 1)
Operating mode display window
Time unit display window
Time unit selector (select one from
sec, min, hrs, and 10 h)
Main dial (for setting a time value)
Nameplate (20 x 5.4 mm white panel)
Setting
Output Type Selector Switch Settings
Time-limit output (terminal numbers 25, 26 and
28) (default setting)
Instantaneous output
(terminal numbers 21, 22 and 24)
Output type

Related parts for H3DE-M2 DC12