H5CX-A11 AC100-240 Omron, H5CX-A11 AC100-240 Datasheet - Page 27

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-A11 AC100-240

Manufacturer Part Number
H5CX-A11 AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-A11 AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
11 Pin Socketable
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5CX-A11-AC100-240
H5CXA11AC100240
Z2369
Settings for Advanced Functions
Settings that cannot be performed with the DIP switch are performed with the operation keys.
(See note 1.)
3 s min.
Power ON
(See note 2.)
3 s min.
OFF time
range
ON time
range
Timer mode
ON/OFF
start mode
Input signal
width
NPN/PNP
input mode
Display color
Key protect
level
(Flicker OFF
start)
(NPN input) (PNP input)
For details on operations in run mode, refer to page 29.
Note 1. If the mode is switched to the function setting mode during operation, operation will
The characters displayed in reverse video are the initial values.
When performing settings with operation keys only, set pin1 of the
DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set
to ON, the setting items indicated by
Set the OFF time range using the
Set the ON timer range using the
Set the timer mode using the
Set the twin timer output mode using the
Set the input signal width using the
Set the NPN/PNP input mode using the
Only displayed for H5CX-A@ and H5CX-A11@ models.
Set the display color using the
Displayed for terminal-block models (H5CX-A@) only.
Set the key protect level using the
(Elapsed
time)
For details, refer to Time Range List below.
For details, refer to Time Range List below.
(20 ms)
(Red) (Green) (Red-green) (Green-red)
(KP-1)
2. Changes made to settings in function setting mode are enabled for the first time when
s
s
continue.
the mode is changed to run mode. Also, when settings are changed, the timer is reset
(time initialized and output turned OFF).
(Remaining
time)
(Flicker ON
start)
(1 ms)
(KP-2)
s
s
(KP-3)
s
s
(KP-4)
keys.
keys.
......
......
will not be displayed.
keys.
keys.
keys.
keys.
(KP-5)
keys.
keys.
h
h
s
s
Display
Time Range List
0 h 01 min to 99 h 59 min
0.1 h to 999.9 h
0.01 s to 99.99 s (default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to 99 min 59 s
0.1 min to 999.9 min
1 min to 9999 min
1 h to 9999 h
0.001 s to 9.999 s
Set Value
H5CX-A/-L
27