I3000S Fluke Electronics, I3000S Datasheet

no-image

I3000S

Manufacturer Part Number
I3000S
Description
CURRENT CLAMP AC
Manufacturer
Fluke Electronics
Type
AC Clampr
Datasheets

Specifications of I3000S

Style
Pincer
Ac Current Range
1 ~ 3000A
Bandwidth
100kHz
Cable Length
82.377" (2100.00mm)
Max Conductor Size
2.520" (64.00mm)
Termination
BNC
Ratings
CAT III 600V
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
657202
Introducing the i3000s
The i3000s is a clamp-on AC Current Clamp for use with
oscilloscopes and multimeters with banana input using the supplied
Dual Banana to BNC Adapter. The clamp is optimized for
measurement on power distribution systems.
Unpacking
The following items should be included in your Current Clamp box:
Check the contents of the shipping box for completeness. If
something in the box has been damaged or missing, contact your
distributor or the nearest FLUKE sales or service office immediately.
Safety Information
To ensure safe operation and service of the
current clamp, follow these instructions:
October 1997, Rev.3, 08/05
© 1997 -2005 Fluke Corporation.
All rights reserved.
Printed in the Netherlands
All product names are trademarks
of their respective companies.
Current Clamp
Dual Banana to BNC Adapter (model PM9081/001)
Instruction Sheet (this paper)
Read the operating instructions before use and follow all
safety instructions.
Use the Current Clamp only as specified in the operating
instructions, otherwise the clamp’s safety features may
not protect you.
Adhere to local and national safety codes. Individual
protective equipment must be used to prevent shock and
arc blast injury where hazardous live conductors are
exposed.
Do not hold the Current Clamp anywhere beyond the
tactile barrier, see Figure 8.
Before each use, inspect the Current Clamp. Look for
cracks or missing portions of the clamp housing or output
cable insulation. Also look for loose or weakened
components. Pay particular attention to the insulation
surrounding the jaws.
Check the magnetic mating surfaces of the clamp jaws;
these should be free of dust, dirt, rust and other foreign
matter.
Never use the clamp on a circuit with voltages higher than
600 V CAT III.
transients in equipment in fixed equipment
installations, such as distribution panels, feeders and
short branch circuits, and lighting systems in large
buildings.
CAT III equipment is designed to protect against
Read First: Safety Information.
AC Current Clamp
Instruction Sheet
i3000s
®
Symbols
Specifications
SAFETY
ELECTRICAL SPECIFICATIONS
CE Conformity
All Electrical Specifications are valid at the following reference
conditions:
Use extreme caution when working around bare
conductors or bus bars. Contact with the conductor could
result in electric shock.
Use caution when working with voltages above 60 V dc,
30 V ac rms or 42 V ac peak. Such voltages pose a shock
hazard.
Ambient temperature
Relative Humidity
Frequency
Continuous external field
Load impedance
The current may not contain any DC component
No influence from adjacent currents
The conductor must be centered within the jaw aperture
Input jaws &
Output float voltage
May be used on HAZARDOUS LIVE conductors.
Product is protected by double insulation.
Risk of Danger. Important information. See
Instruction Sheet.
Risk of Electric Shock.
Conforms to relevant European standards.
Earth ground
23±3°C (73±3°F)
0 to 85%
48 to 65 Hz
< 40 A/m
1 M
Complies with European
standards EN/IEC 61010-1
2nd Edition & EN/IEC 61010-
02-032 for 600V CAT III,
pollution degree 2.
EN/IEC 61010-02-032
// 47 pF
Measuring range
Crest factor *
Maximum non-
destructive current:
Output signal
Basic accuracy
Additional errors:
Phase shift
*
GENERAL
Bandwidth (-3dB)
Clamp Dimensions
Weight
Cable length
Maximum conductor size
Maximum Jaw Opening
Temperature
Relative Humidity
Altitude
This is the maximum permissible ratio between the peak value
of a superimposed transient and the ac rms value.
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
continuous
30min.+30min.
stop
5min.+30min.
stop
with
temperature
(-10 to +50°C)
with position of
conductor in
the clamp
window
with adjacent
conductor
with frequency
(10Hz to 100
kHz)
(see Figure 7 for derating)
1 to 30A ac
up to 3
36A
10 mV/A
2% of reading
+ 0.1A
0.02%/°C
1% + 0.1A
0.005A/A
See Figure 1
20° @ 2A
10° @ 8A
5° @ 30A
See Figure 4
30A
10 Hz to 100 kHz
310 x 120 x 48 mm
(12.2 x 4.7 x 1.9 in)
1200 g (42.3 oz)
2.1 m (82.6 in)
∅ 64 mm (2.5 in)
90 mm (3.5 in)
-10 to +50°C (+14 to +122°F)
-40 to + 85°C (-40 to +185°F)
0 to 85%, up to +35°C (+95°F)
0 to 75%, up to +50°C (+122°F)
0 to 85%, up to -10°C (+14°F)
0 to 75%, up to +85°C (+185°F)
to 2000 m (6500 ft)
to 12000 m (40000 ft)
Current Ranges
1 to 300A ac
up to 3
360A
1 mV/A
2% of reading
+ 0.5A
0.02%/°C
1% + 0.1A
0.005A/A
See Figure 2
3° @ 20A
1.5° @ 80A
1° @ 300A
See Figure 5
300A
1 to 3000 A ac
up to 3
2400A
2800A
4000A
0.1 mV/A
2% of reading
+ 2A
0.02%/°C
1% + 0.1A
0.005A/A
See Figure 3
3° @ 200A
1.5° @ 800A
1° @ 3000A
See Figure 6
3000A
FREQUENCY RESPONSE
30A Range
300A Range
3000A Range
Figure 3. Frequency Response @ 100A
Figure 1. Frequency Response @ 10A
Figure 2. Frequency Response @ 10A

I3000S Summary of contents

Page 1

... Symbols AC Current Clamp Instruction Sheet Introducing the i3000s The i3000s is a clamp-on AC Current Clamp for use with oscilloscopes and multimeters with banana input using the supplied Dual Banana to BNC Adapter. The clamp is optimized for measurement on power distribution systems. Unpacking Specifications The following items should be included in your Current Clamp box: • ...

Page 2

... A passband of more than four times the frequency of the waveform to be measured. Connect the i3000s Current Clamp to the desired input on the measuring instrument. When you are using a multimeter, use the Dual Banana to BNC Adapter (PM9081/001) to connect the Current Clamp to the input ...