TP912 Fluke Electronics, TP912 Datasheet - Page 42

no-image

TP912

Manufacturer Part Number
TP912
Description
REPLACEMENT TIPS FOR TL910
Manufacturer
Fluke Electronics
Datasheet

Specifications of TP912

Tip - Type
Fine Tip, 0.039" (1.00mm) Dia
Current Rating
3A
Termination
For Use on TL910 Probe
Material - Tip
Steel, Stainless
Ratings
CAT IV, 600V; CAT III, 1000V
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Voltage Rating
-
Operating Temperature
-
Color
-
Material - Body
-
Length - Total
-
Length - Tip
-
Other names
1616644

Specifications – 715, 707 and 705
1
Recommended accessories – 715, 707, 707Ex and 705 Calibrators
For more information and detailed specifications, go to www.fluke.com/loop
Process Calibration Tools
Will over-range to 24 mA
Functions
Voltage measurement
Range
Resolution
Accuracy
Current measurement
Range
Resolution
Accuracy
Current sourcing
Range
Accuracy
Drive capability
Loop power while measuring mA
Voltage sourcing
Display current and % of span
Auto step, auto ramp
Span Check
Battery life
Test Lead Set
See page 62
Heavy Duty
TL8A
Complete family of volt/mA calibrators
SureGrip Industrial
Test Lead Set
See page 61
705 Loop Calibrators
TL0
Fluke 715, 707 and
705: 1000 W @ 24 mA 707: 1200 W @
Fluke 707 and 705
Two powerful models to choose from
Intrinsically safe 707 version available (see page 45)
705: 0.025 % Rdg + 1 LSD 707,
705: 0.025 % Rdg + 2 LSD 707,
24 mA 707Ex: 700 W @ 20 mA
705: 0.02 % Rdg + 2 LSD 707,
707Ex: 0.015 % Rdg + 2 LSD
707Ex: 0.015 % Rdg + 2 LSD
707Ex: 0.015 % Rdg + 2 LSD
Innovative output adjustment dial on 707 provides
1 µA and 100 µA resolution and one-hand operation
Large display and simple interface for ease of use
Simultaneous mA and % readout for quick, easy
interpretation of readings
mA accuracy of 0.015 % on the Fluke 707 and 0.02 %
on the 705
HART
series with 24 V loop for compatibility with HART
communicators
Push button 25 % steps for fast, easy linearity checks
“Span Check” for fast confirmation of zero and span
Selectable slow and fast linear step ramp provide
ramping outputs for valve slewing, remote testing
and loop functional tests
24 V internal loop supply, so you can power and read
a transmitter at the same time without carrying a DMM
0 mA to 20 mA or 4 mA to 20 mA default start
up modes
18 hours typical, at 12 mA
0 to 20 mA or 4 to 20 mA
Large Soft Case
Fluke 705 and 707
See page 70
0 to 24 mA
C5
0.001 mA
0 to 28 V
mode on 707 connects 250 ohm resistor in
1 mV
24 V
N/A
Yes
Yes
Yes
1
See page 70
Tool Bag
C550
0 to 200 mV
10 µV
18 hours typical, at 12 mA
0 to 20 mA or 4 to 20 mA
0 to 200 mV or 0 to 20 V
0.01 % Rdg + 2 LSD
0.01 % Rdg + 2 LSD
1000 W @ 24 mA
0.01 % + 2 LSD
0 to 24 mA
Fluke 715
0.001 mA
Pressure Vacuum
mA or %
24 V
See page 65
Yes
Yes
PV50
Module
0 to 25 V
1 mV
1
Fluke 715 Volt/mA Calibrator
Application note, literature
code 1989137:
Troubleshooting
process loops
In process
systems, prob-
lems with
the loop can
bring things to
a screeching
halt. In this
application
note, find out
how to use
Fluke test tools
to identify
current loop
prolems such
as noise,
ripple and drift.
Source voltage to 200 mV or 20 V
Measure loop current (0 to 20 mA,
4 to 20 mA) signals with 0.01 %
accuracy and 1 µA resolution
Measure voltage output process
signals from PLCs, transmitters
Source or simulate 24 mA
loop current
24 V loop supply with simultaneous
current measurement
Ramp and Step Ramp output functions
Included accessories
Fluke 715: Protective yellow hol-
ster, test leads and alligator clips,
single 9 V alkaline battery and
instruction sheet (14 languages).
Fluke 705, 707 and 707Ex:
Protective holster, TL75 Test Leads,
AC72 Test Clips and instruction
sheet (14 languages).
Ordering information
Fluke-715
Fluke-707
Fluke-707Ex IS Loop Calibrator
Fluke-705
Volt/mA Calibrator
Loop Calibrator
Loop Calibrator