80PK-24 Fluke Electronics, 80PK-24 Datasheet

no-image

80PK-24

Manufacturer Part Number
80PK-24
Description
PROBE AIR TEMP SUREGRIP TYPE-K
Manufacturer
Fluke Electronics
Series
SureGrip™r
Type
K-Type Thermocoupler
Datasheets

Specifications of 80PK-24

Usage
HVAC
Tip - Type
Air, Caged
Plug Type
Sub-Mini (Thermocouple Plug)
Probe Temperature Range
-40 ~ 1500°F (-40 ~ 816°C)
Cable Length
39.370" (1000.00mm)
Cable Insulation
Poly-Vinyl Chloride (PVC)
Plug Color
Yellow
Probe Length
8.500" (215.90mm)
Probe Material
Inconel
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
2098691
Introduction
The 80PK-24 SureGripTM Air Temperature Probe is
designed for measuring the temperature of air or gases.
The measuring bead of the probe is protected by a
perforated 304 Stainless Steel baffle to prevent accidental
damage. The sheath material is 300 Stainless Steel. The
38-inch (1 meter) cable is terminated with a Type K
miniature thermocouple connector with 0.792-mm (.312-in)
pin spacing. The 80PK-24 can be used with any
temperature-measuring instrument that is designed to
accept Type K thermocouples and has a miniature
connector input.
Specifications
Type
K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
Measurement Range
Accuracy
(With respect to ANSI MC96.1-1982-Standard Limits of
Error):
November 2004
© 2004 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies
-40 C to 816 C (-40 F to 1500 F)
-40 C to 0 C
(-40 F to 32 F)
0 C to 275 C
(32 F to 527 F)
275 C to 816 C
(527 F to 1500 F)
SureGrip
To avoid electrical shock, do not use this
probe when voltages exceeding 24 V ac rms
or 60 V dc are present. The probe tip is
electronically connected to the output
terminals.
All error calculations should be done in C, then
scaled to F.
Range
XWWarning
TM
Air Temperature
Note
±2.2 C
±1.1 C
±0.4 %
Instruction Sheet
80PK-24
(% of reading)
Accuracy
Probe
®

80PK-24 Summary of contents

Page 1

... Stainless Steel baffle to prevent accidental damage. The sheath material is 300 Stainless Steel. The 38-inch (1 meter) cable is terminated with a Type K miniature thermocouple connector with 0.792-mm (.312-in) pin spacing. The 80PK-24 can be used with any temperature-measuring instrument that is designed to accept Type K thermocouples and has a miniature connector input. ...

Page 2

Output @ 25 C (77 F) =1.00 mV (reference junction @ 0 C) Seebeck Coefficient @ 25 C (77 F) =40. Measurement Time (Time Constant) 3.0 seconds in 100 C air moving at 3.33 meters/second (10.9 feet/ ...

Page 3

... If the instrument does not read out properly, refer to “Troubleshooting”. Minimizing Thermal Shunting The 80PK-24 Air Probe should be inserted at least 6.35 cm (2.5 in) into the environment to be measured to minimize the shunting effect of the sheath. ...

Page 4

... If you suspect a broken connection, use an ordinary ohmmeter to read the continuity of the probe from pin to pin. The ohmmeter should read 20 ohms or less if there is continuity. Scale Conversions Use the following equation to convert 1. Use the following equation to convert –32) x 0.5556 = C Figure 2. 80PK-24 bag01f.eps ...

Page 5

For application or operation assistance, or information on Fluke products, call: USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at ...