1. INTRODUCTION
Terminating Modules 791804–[ ] are designed to be
used with Modular Plug Dual Terminators 1320840–[ ]
or 856195–6. This combination terminates each
modular plug listed in Figure 1 to create a cable
assembly and tests it for electrical circuit continuity.
Read these instructions completely before using the
module.
Reasons for reissue of this instruction sheet are
provided in Section 9, REVISION SUMMARY.
When reading this document, pay particular attention
to DANGER and CAUTION statements.
2. DESCRIPTION
These modules fit interchangeably into a modular
plug dual terminator. Each module features dual
nesting areas for positioning the modular plugs,
inserters for terminating the contacts, and stuffers for
terminating the primary and secondary strain reliefs.
Since each feature is independently adjustable, crimp
heights are easily adjusted to meet International
Electrotechnical Commission (IEC) specifications.
Each terminator consists of a pneumatic power unit, a
automatic circuit tester with cable hook–up and
Terminating Modules 791804-[ ]
Back of Terminator 1320840-1 Ref
2
CAUTION
DANGER
of 7
!
Connect Green Wire of Tester Cable to
Suitable Ground on AC Outlet
Denotes an imminent hazard which may result in
moderate or severe injury.
Denotes a condition which may result in product
or equipment damage.
Tyco Electronics Corporation
Figure 2
ground, and an AC/DC converter. The tester can be
set to test specific modular plug sizes and contact
arrangements. Test results are signaled by a beeper;
specific information is displayed by means of a series
of light–emitting diodes (LED) on the front panel of
the tester. The noise level produced by the terminator
varies between 82 and 87 dB at the operator position.
3. INSTALLATION
3.1. Terminating Module
DANGER
1. Install Terminator 1320840–[ ] according to
Customer Manual 409–10010, or install Terminator
856195–6 according to the documentation included
with the terminator. Plug the base unit into:
2. DISCONNECT the air supply.
3. Remove the plastic guard from the module by
removing four screws and two terminals from the
limit switch (refer to the customer drawing for the
module for location).
4. Connect the cable from the automatic circuit
tester to the rear of the module, and tighten the
screws to secure cable. Refer to Figure 2.
TERMINATOR
1320840-1
1320840-2
856195-6
To avoid personal injury, DISCONNECT AIR
SUPPLY before attempting to install or remove
the module from the terminator. A lockout valve
has been provided in the air line.
T ester Cable Connected
to Rear of Module
115 Vac, 60Hz
230 Vac, 50Hz
220 Vac, 50Hz
SERVICE
408-8734
Rev
C