UT-40SI Master Appliance Co, UT-40SI Datasheet - Page 2

TOOL HEAT UTLRTRCH SELF-IGNITING

UT-40SI

Manufacturer Part Number
UT-40SI
Description
TOOL HEAT UTLRTRCH SELF-IGNITING
Manufacturer
Master Appliance Co
Series
Ultratorch®r
Type
Butane Torch, Flamelessr
Datasheets

Specifications of UT-40SI

Temperature Range
1202°F (650°C)
Features
Includes: Heat Gun and 2 Nozzles
Rohs Compliant
NA
Brand/series
UT-40
Lead Free Status / RoHS Status
Not applicable / Not applicable
Voltage
-
Power - Rated
-
Lead Free Status / Rohs Status
RoHS Exempt Product
Other names
MA1021
This product uses a catalytic gas
reaction system. The special
catalyst contained in the tip is
preheated with a butane flame.
The preheated flame is
extinguished when the shutter is
closed over the ignition vent.
Use only Master Ultratane butane with your Ultratorch.
Do not fill gas or store near open flame, heater, furnace or
combustible materials. Make sure the unit is cool before
re-fueling. Fill gas holding the unit firmly with the refill
nozzle pointed upwards and press down. Gas will overflow
from nozzle when tank is full.
1. Be sure the exhaust opening is positioned upward. Keep hands and
2. Set the gas Control lever in the middle of the + and -. (In cold places
3. Push the ignition lever upward slowly until it clicks. After several
4. Adjust tip temperature with the gas control lever.
5. To turn off, push GAS OFF BUTTON. Check window to make sure the
1. Loosen knurled nut to remove tip and tip housing.
2. Replace with soldering tip or hotblow tip and re-install tip housing
DO NOT TRY TO IGNITE WHEN SOLDERING OR HEAT TIP IS
DISMOUNTED. THIS COULD LEAD TO AN IGNITION PROBLEM.
Change ejector unit when gas does not flow, ceramic burner is broken or
used up after a certain amount of time, etc.
TO REMOVE
1. Remove a soldering/heat tip by
2. Insert a bar into the hole on the
1. Allow unit to cool and put protective cap on for storage.
2. If your unit is not going to be used for awhile, store in the following
3. Leave tank approximately 1/2 full so lubrication of fuel pickup filter
4. Set flow control valve at mid setting.
Butane gas continues to flow over the preheated catalyst generating infrared
heat which is either conducted through the soldering iron tip or passed through
the heat tip as hot gas.
Principles of Operation
Fill with Ultratane
Use as a Soldering Iron or Heat Tool
To Replace Ejector
Storage of Your Ultratorch Heat Tool
Ignition Instructions
combustibles clear of exhaust opening and tip housing to avoid burns
or fire.
or soon after refueling, move lever towards + and in hot, towards -.
seconds, the window becomes red and the catalyst starts to react
without a flame inside. If the unit did not ignite, push the OFF button
and repeat.
unit is off.
onto unit.
loosening the knurled nut.
ejector and turn clockwise. The
ejector unit will come away.
(fig 2)
manner. Store in proper location avoiding elevated temperatures and
away from children.
stays wet.
Butane
Chrome Plated
2
Tinned
Iron Plated
TO REMOUNT
1. Replace with new ejector unit
2. Replace a tip and tighten the
and insert a bar in the hole on
ejector and turn counter-clock-
wise to tighten.
knurled nut. (fig 3)
Hot Air Vent Catalyst
Copper Base Nickel Plated
Form No. 58175 Rev. 2
Evaporated
Gas
1
3