CST306-3A Triad Magnetics, CST306-3A Datasheet

TRANSF 55MH CRNT SENSE

CST306-3A

Manufacturer Part Number
CST306-3A
Description
TRANSF 55MH CRNT SENSE
Manufacturer
Triad Magnetics
Series
CST306r
Type
Current Senser
Datasheets

Specifications of CST306-3A

Transformer Type
Frequency 20-200kHz
Turns Ratio - Primary:secondary
1 : 200
Inductance
55mH
Current Rating
25A
Dc Resistance (dcr)
3.75 Ohm Max
E.t.
2000V µS
Mounting Type
PCB
Frequency Range
20 KHz to 200 KHz
Termination Style
Radial
Dimensions
17.53 mm L x 9.78 mm W x 23.24 mm H
Product
Current Sense Transformers
Brand/series
CST Series
Configuration
Encapsulated
Current, Primary
25 A
Frequency
20-200 kHz
Number Of Outlets
1
Number Of Turns
200
Phase
1
Resistance, Dc
3.75 Ohms
Resistance, Dc, Primary
250 μOhms (Max.)
Resistance, Dc, Sence
21 Ohms (Max.)
Standards
UL
Temperature Rating
130 °C
Temperature, Operating
+40 °C
Termination
Thru-Hole
Turns Ratio
1:500
Input Current
25A
Dc Resistance Max
3.75ohm
Rohs Compliant
Yes
Transformer Mounting
Through Hole
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
237-1108
CST306-3A
Description:
Designed for switching power supply applications, Triad current sense
transformers are used to detect the current passing through a conductor.
These transformers are very reliable and operate over the frequency range of
20 kHz-200 kHz.
Electrical Specifications (@25C)
Safety:
These current sense transformers are constructed of UL rated 130°C materials.
Dimensions:
.180
Units: In inches
Technical Notes:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
Min
RoHS Compliance:
A
REF 20kHz
ET VµSEC
1. START OF TEST CONDUCTOR TO HAVE
2. DECAL ARROW ON CASE TO INDICATE
1. Derate ET product by 32% for 50 kHz, 52% for 100 kHz and 50% for
2. Rated primary current renders approximately 40°C temp. rise.
3. Maximum recommended terminating resistance of 1 ohm per turn.
4. Primary is inserted through hole in casting.
THE SAME POLARITY AS PIN 1
POLARITY
2000
Max
.915
unidirectional operation.
B
.528
Ref
C
Count
Turns
.127
Ref
200
D
As of manufacturing date February 2005, all standard
.500
Ref
E
Max
.385
Ind. mH
F
Min.
55.0
1
Max
.690
G
Dia. Pins
DCR Max. Ω
PIN 1
ARROW
.032
ST
POLARITY DETAIL TOP VIEW
H
3.750
Current Sense Transformers
Pri. Amps
25.0 RMS
TEST CONDUCTOR
A
D
F
G
C
C L
H
B

Related parts for CST306-3A

CST306-3A Summary of contents

Page 1

... CST306-3A Description: Designed for switching power supply applications, Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate over the frequency range of 20 kHz-200 kHz. Electrical Specifications (@25C) ET VµSEC Turns REF 20kHz Count Ind ...

Page 2

... CT B CST306-2A 1000 100 A CST306-2T 1000 100 CT B CST306-3A 2000 200 A CST306-3T 2000 200 CT 3. CST206 models have maximum recommended terminating resistance of 1 ohm per turn. 4. Primary is inserted through hole in casing pin or center tapped (CT) models are designed with a T suffix. Turns ...

Page 3

... Turns ratio: Primary to sense 1:500 2. Suggested burden resistor: 60 ohms. 3. Typical ouput: 110 mV /Amp Triad current sense transformers are used to detect the current passing through a conductor. These transformers are very reliable and operate effectively between 50-60 Hz. They are constructed of UL rated 130ºC materials ...

Related keywords