FP12-475 Triad Magnetics, FP12-475 Datasheet

TRANSF 6.3VAC .95A FLAT PACK PWR

FP12-475

Manufacturer Part Number
FP12-475
Description
TRANSF 6.3VAC .95A FLAT PACK PWR
Manufacturer
Triad Magnetics
Type
Dual Primaryr
Datasheets

Specifications of FP12-475

Maximum Power
6 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
12.6 VAC @ 475mA
Parallel Output Voltage @ Current
6.3 VAC @ 950ma
Mounting Type
Through Hole
Power Rating
6 VA
Product
Flat Pack Transformers
Brand/series
Flat Pack™
Configuration
Toroidal
Current, Secondary
0.95/0.475 A
Dielectric Strength
2000 V (RMS)
Dimensions
1.875"L×1.562"W×0.875"H
Frequency
50/60 Hz
Number Of Outlets
2
Phase
1
Power, Rating
6 VA
Standards
UL, cUL
Termination
Thru-Hole
Voltage, Primary
115/230 VAC
Voltage, Secondary
6.3/12.6 VAC
Weight
7 Oz.
Primary Voltage Rating
115 V / 230 V
Secondary Voltage Rating
6.3 V / 12.6 V
Mounting Style
SMD/SMT
Height
0.875 in
Length
1.562 in
Termination Style
Solder
Width
1.875 in
Current Rating
950mA
Output Current, Secondary Series
0.475A
No. Of Pins
8
External Height
0.875"
Output Current, Secondary Parallel
0.95A
Rohs Compliant
Yes
Secondary Voltages
2 X 6.3V
Transformer Mounting
Surface Mount
External Depth
1.875"
External Width
1.562"
Input Voltage
115VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10432
237-1017

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FP12-475
Manufacturer:
Triad Magnetics
Quantity:
135
FP12-475
Electrical Specifications (@25C)
1. Maximum Power: 6.0 VA
2. Primary Voltage:
3. Secondary:
Description:
The FP12-475 is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 2000V between
primary and secondary windings and 1500V between the primary / secondary
windings and the core.
Agency File:
UL: File E53148, UL 506, Class B General Purpose Transformer,
cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use
Dimensions:
1.875
Units: In inches
Weight: 7.0 oz
Pin Dimension: .020 x .041 in
Schematic:
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
A
Series: 230V@50/60 Hz
Parallel: 115V@50/60Hz
Series:
Parallel: 6.3V @ 0.950 Amps
1.562
B
12.6VCT @ 0.475Amps
0.875
C
As of manufacturing date February 2005, all standard
0.267
D
1
2
4
3
0.375
E
22520B Temescal Canyon Road
Corona, California
92883
1.600
F
5
6
8
7
Power Transformer
PC Mount: Flat Pack
Publish: August 7, 2006
.060 DIA HOLES
A
7
3
E
4
8
B
E
6
2
E
5
1
F
D
C

Related parts for FP12-475

Related keywords