166G28 Hammond Manufacturing, 166G28 Datasheet

TRANSFORMER 115VAC 28VCT .5A

166G28

Manufacturer Part Number
166G28
Description
TRANSFORMER 115VAC 28VCT .5A
Manufacturer
Hammond Manufacturing
Type
Single Primaryr
Series
166r
Datasheets

Specifications of 166G28

Maximum Power
14 VA
Primary Winding(s)
Single
Secondary Winding(s)
Single, Center Tap
Series Output Voltage @ Current
28 VAC @ 500mA
Mounting Type
Chassis Mount
Primary Voltage Rating
115 V
Secondary Voltage Rating
28 V
Mounting Style
Through Hole
Dimensions
71.37 mm L x 41.4 mm W x 42.93 mm H
Product
Power Transformers
Height
42.93 mm
Length
71.37 mm
Number Of Outputs
1
Operating Temperature Range
0 C to + 130 C
Termination Style
Solder Pin
Width
41.4 mm
Brand/series
166 Series
Configuration
Bobbin
Current, Secondary
0.5 A
Frequency
60 Hz
Length, Lead
6 "
Mounting Hole Centers
2.38 "
Number Of Outlets
2
Phase
1
Power, Rating
14 VA
Standards
UL, CSA
Termination
Leadwires
Voltage, Primary
115 VAC
Voltage, Secondary
28 (C.T.) VAC
Current Rating
500mA
Power Rating
14VA
Transformer Mounting
Chassis
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Transformer Type
Bobbin
Primary Type
Single
Supply Voltage
115V
Rohs Compliant
Yes
Primary Voltages
1 X 115V
Input Voltage
115VAC
Leaded Process Compatible
No
Output Current
0.5A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Parallel Output Voltage @ Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
HM559
Key Features:
Economical single primary 115 VAC, 60 Hz. (or 117 50/60 Hz. see table)
you require 117/234 or 50/60 Hz. operation or dual secondaries check out our
versatile
All secondaries center tapped, VAC (RMS)
Open style, channel bracket, two hole chassis mount.
Minimum 6" long leads.
Dual bobbin design - no electrostatic shield required.
We use Class B insulation (130 degrees, C) for extra protection - UL listed as a
Class A (105 degree, C) design
Hi-Pot test of 2,000V RMS.
UL listed.
CSA certified.
166F2
166G2
166J2
166K2
Part No.
266 series
0.63
1.25
3.75
)
VA
2.5
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
Filament & L.V. Rectifier Use Transformers
Primary
Open Style - Economical Single Primary
(VAC)
Secondary (R.M.S.)
2.5 C.T.
2.5 C.T.
2.5 C.T.
2.5 C.T.
Chassis Mount
VAC
Amps
0.25
0.5
1.5
1
Dim. Ref.
C2H
C2H
C3H
C4H
- (If

Related parts for 166G28

166G28 Summary of contents

Page 1

... We use Class B insulation (130 degrees, C) for extra protection - UL listed as a Class A (105 degree, C) design Hi-Pot test of 2,000V RMS. UL listed. CSA certified. Part No. 166F2 166G2 166J2 166K2 Open Style - Economical Single Primary Filament & L.V. Rectifier Use Transformers ) Secondary (R.M.S.) Primary VA (VAC) 0.63 115V 60 Hz. 2.5 C.T. 1.25 115V 60 Hz. ...

Page 2

... Hz. 166L25 50 115V 60 Hz. 166M25 75 115V 60 Hz. 166L25B 50.4 115V 50/60 Hz. 166F28 7 115V 60 Hz. 166G28 14 115V 60 Hz. 166J28 28 115V 60 Hz. 166L28 56 115V 60 Hz. 166E30 4.5 115V 60 Hz. 166F30 7.5 115V 60 Hz. 166G30 15 115V 60 Hz. 166J33 33 115V 60 Hz. 166K35 52 ...

Page 3

Mechanical & Schematic Data: "B" Mounting Mtg. Style B1H B2H "C" Mounting Dimensions (Inches 3.44 2.98 4.13 2.75 2.38 0.203 x 0.375 3.75 3.56 4.50 3.00 3.00 0.203 x 0.375 Mtg. Slot (Inches) ...

Page 4

Dimensions (Inches) Mtg. Style A B C0H 1.35 0.69 C1H 1.63 0.88 C2H 2.06 1.25 C3H 2.06 1.38 2.38 1.38 C4H 2.38 1.5 C5H 2.81 1.5 C6H 2.81 1.63 C7H C8H 3.25 1.63 C9H 3.25 1.75 C10H 3.25 2 C11H ...

Page 5

... Filament & L.V. Rectifier Use - Single Primary (166 Series) OPEN STYLE FILAMENT & L.V. RECTIFIER USE TRANSFORMERS • Economical single primary 115 VAC, 60 Hz. or 117 VAC, 50/60 Hz. (see tables). If you require dual primary 117/234 operation, see our 266 series) • All secondaries center tapped, VAC (RMS) • ...

Page 6

... V 60 Hz. 166M25 0.7 C7H 75 115 V 60 Hz. 1 C7H 166L25B 50.4 115 V 50/60 Hz. 1.2 C8H 166F28 7 115 V 60 Hz. 1.2 C9H 166G28 14 115 V 60 Hz. 21 Secondary (R.M.S.) Dim Ref. VAC Amps 12 C.T. 2 C9H 12 C.T. 4 C12H 12.6 C.T. 0.3 C4H 12.6 C.T. 0.5 C6H 12 ...

Page 7

Filament & L.V. Rectifier Use - Single Primary (166 Series) Secondary (R.M.S.) Part No. VA Primary VAC 166J28 28 115 V 60 Hz. 28 C.T. 166L28 56 115 V 60 Hz. 28 C.T. 166E30 4.5 115 V 60 Hz. 30 ...

Related keywords