166Q2 Hammond Manufacturing, 166Q2 Datasheet

TRANSFORMER 115VAC 2.5VCT 6A

166Q2

Manufacturer Part Number
166Q2
Description
TRANSFORMER 115VAC 2.5VCT 6A
Manufacturer
Hammond Manufacturing
Type
Single Primaryr
Series
166r
Datasheets

Specifications of 166Q2

Maximum Power
15 VA
Primary Winding(s)
Single
Secondary Winding(s)
Single, Center Tap
Series Output Voltage @ Current
2.5 VAC @ 6A
Mounting Type
Chassis Mount
Primary Voltage Rating
115 V
Secondary Voltage Rating
2.5 V
Mounting Style
Through Hole
Dimensions
82.6 mm L x 41.4 mm W x 42.9 mm H
Product
Power Transformers
Height
42.9 mm
Length
82.6 mm
Number Of Outputs
1
Operating Temperature Range
0 C to + 130 C
Termination Style
Solder Pin
Width
41.4 mm
Application
For rectifier use
Brand/series
166 Series
Configuration
Bobbin
Current, Secondary
6 A
Frequency
60 Hz
Hipot Rating
2000 V (RMS)
Length, Lead
6 "
Mounting Hole Centers
2.81 "
Number Of Outlets
2
Phase
1
Standards
UL, CSA
Termination
Leadwires
Voltage, Primary
115 VAC
Voltage, Secondary
2.5 (C.T.) VAC
Current Rating
6A
Power Rating
15VA
Transformer Mounting
Chassis
Transformer Type
Bobbin
Supply Voltage
115V
Output Voltage
2.5V
Output Current
6A
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Input Voltage
115VAC
Primary Voltages
1 X 115V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Parallel Output Voltage @ Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
HM502
Key Features:
Economical single primary 115 VAC, 60 Hz. (or 117 50/60 Hz. see table)
operation or dual secondaries check out our versatile
All secondaries center tapped, VAC (RMS)
Open style, channel bracket, two hole chassis mount.
Minimum 6" long leads.
Dual bobbin design - no electrostatic shield required.
We use Class B insulation (130 degrees, C) for extra protection - UL listed as a Class A (105 degree, C) design
Hi-Pot test of 2,000V RMS.
UL listed.
CSA certified.
166F2
166G2
166J2
166K2
166L2
166M2
166Q2
166S2
166F5
166G5
166J5
166L5
166MS
166R5
166RS
Part No.
0.63
1.25
3.75
6.25
1.25
VA
2.5
7.5
2.5
15
25
10
15
40
40
5
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
115V 60 Hz.
Primary
(VAC)
Filament & L.V. Rectifier Use Transformers
Open Style - Economical Single Primary
266 series
Secondary (R.M.S.)
2.5 C.T.
2.5 C.T.
2.5 C.T.
2.5 C.T.
2.5 C.T.
2.5 C.T.
2.5 C.T.
2.5 C.T.
5 C.T.
5 C.T.
5 C.T.
5 C.T.
5 C.T.
5 C.T.
5 C.T.
VAC
)
Chassis Mount
Amps
0.25
0.25
0.5
1.5
2.5
0.5
10
1
3
6
1
2
3
8
8
- (If you require 117/234 or 50/60 Hz.
Dim. Ref.
C12H
C12H
C16H
C2H
C2H
C3H
C4H
C6H
C6H
C8H
C2H
C3H
C5H
C7H
C9H

Related parts for 166Q2

166Q2 Summary of contents

Page 1

... We use Class B insulation (130 degrees, C) for extra protection - UL listed as a Class A (105 degree, C) design Hi-Pot test of 2,000V RMS. UL listed. CSA certified. 166F2 166G2 166J2 166K2 166L2 166M2 166Q2 166S2 166F5 166G5 166J5 166L5 166MS 166R5 166RS Open Style - Economical Single Primary Filament & ...

Page 2

Hz. 166F28 7 115V 60 Hz. 166G28 14 115V 60 Hz. 166J28 28 115V 60 Hz. 166L28 56 115V 60 Hz. 166E30 4.5 115V 60 Hz. 166F30 7.5 115V 60 Hz. 166G30 15 115V 60 Hz. ...

Page 3

... Filament & L.V. Rectifier Use - Single Primary (166 Series) OPEN STYLE FILAMENT & L.V. RECTIFIER USE TRANSFORMERS • Economical single primary 115 VAC, 60 Hz. or 117 VAC, 50/60 Hz. (see tables). If you require dual primary 117/234 operation, see our 266 series) • All secondaries center tapped, VAC (RMS) • ...

Page 4

... V 60 Hz. 2.5 C.T. 166K2 3.75 115 V 60 Hz. 2.5 C.T. 166L2 6.25 115 V 60 Hz. 2.5 C.T. 166M2 7.5 115 V 60 Hz. 2.5 C.T. 166Q2 15 115 V 60 Hz. 2.5 C.T. 166S2 25 115 V 60 Hz. 2.5 C.T. 166F5 1.25 115 V 60 Hz. 5 C.T. 166G5 2.5 115 V 60 Hz. ...

Page 5

Filament & L.V. Rectifier Use - Single Primary (166 Series) Secondary (R.M.S.) Part No. VA Primary VAC 166J28 28 115 V 60 Hz. 28 C.T. 166L28 56 115 V 60 Hz. 28 C.T. 166E30 4.5 115 V 60 Hz. 30 ...

Related keywords