165P25 Hammond Manufacturing, 165P25 Datasheet

TRANSFORMER POWER 25VCT 5A

165P25

Manufacturer Part Number
165P25
Description
TRANSFORMER POWER 25VCT 5A
Manufacturer
Hammond Manufacturing
Type
Single Primaryr
Series
165r
Datasheet

Specifications of 165P25

Maximum Power
125 VA
Primary Winding(s)
Single
Secondary Winding(s)
Single, Center Tap
Series Output Voltage @ Current
25 VAC @ 5A
Mounting Type
Chassis Mount
Primary Voltage Rating
115 V
Secondary Voltage Rating
25 V
Mounting Style
Through Hole
Dimensions
101.6 mm L x 82.55 mm W x 65.02 mm H
Product
Power Transformers
Height
65.02 mm
Length
101.6 mm
Number Of Outputs
1
Operating Temperature Range
0 C to + 130 C
Termination Style
Solder Pin
Width
82.55 mm
Input Current
5A
Transformer Mounting
Panel
Secondary Current Nom
5A
Primary Voltages
115V
Power Rating
125VA
Terminal Type
Chassis Mount
Transformer Type
Bobbin
Primary Type
Single
Rohs Compliant
Yes
Current Rating
5A
Leaded Process Compatible
Yes
Output Current
5A
Output Voltage
25VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Parallel Output Voltage @ Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
HM557
Queenstown, Australia 61-8-8240-2244
Style
Mtg.
H10
H12
H16
H18
H19
H7
H9
Basingstoke, UK 01256 812812
3.00 3.25 2.56 2.50 3.25 4.00 .22 x .56
3.75 2.63 3.13 3.13 2.50 3.25 .22 x .56
3.75 3.13 3.13 3.13 2.75 3.50 .22 x .56
3.75 3.63 3.13 3.13 3.25 4.00 .22 x .56
4.50 3.88 3.75 3.75 2.75 3.50 .28 x .56
4.50 4.38 3.75 3.75 3.25 4.00 .28 x .56
4.50 4.38 3.75 3.75 3.75 4.50 .28 x .56
Transformer Schematic
A
AUSTRALIA
EUROPE
Dimension Table
Blk
Blk
Dimensions (Inches)
B
C
D
Grn/Yel
E
Grn
Grn
F
Filament & L.V. Rectifier Use (165 Series)
Mtg. Slot
www.hammondmfg.com
19
Primary 115 VAC, 60 Hz.
All secondaries center tapped, VAC (RMS)
Open style, 4 hole frame chassis mount.
Minimum 6" long leads or copper tabs with holes.
Dual bobbin design - no electrostatic shield required.
Class B insulation (130 degrees, C).
Hi-Pot test of 2,000V RMS.
UL listed (# E50394) & CSA certified (# LR3902)
FILAMENT & L.V. RECTIFIER USE
HIGH CURRENT - OPEN FRAME
Part No.
165V10
165U11
165S12
165V12
165S18
165U18
165V18
165T22
165V22
165P25
165S25
165P30
165S30
165P60
165N80
165X5
165V7
165Z3
Primary 115 VAC 60 Hz.
St. Laurent, Quebec (514) 343-9010
TRANSFORMERS
Cheektowaga, NY (716) 630-7030
157.5
150
150
200
165
126
252
180
270
360
264
440
125
250
150
300
300
320
Guelph, Ontario (519) 822-2960
VA
Secondary (R.M.S.)
10.0 C.T.
12.6 C.T.
12.6 C.T.
18.0 C.T.
18.0 C.T.
18.0 C.T.
22.0 C.T.
22.0 C.T.
25.0 C.T.
25.0 C.T.
30.0 C.T.
30.0 C.T.
60.0 C.T.
80.0 C.T.
11.0 C.T.
3.0 C.T.
5.0 C.T.
7.5 C.T.
CANADA
VAC
USA
Amps
50
30
21
20
15
10
20
10
15
20
12
20
10
10
5
5
5
4
Dim.
Ref.
H10
H10
H12
H10
H16
H18
H16
H19
H12
H16
H16
H18
H9
H9
H9
H7
H7
H7
©

Related parts for 165P25