IT243 Schaffner EMC Inc, IT243 Datasheet
IT243
Specifications of IT243
817-1510
IT 243
Available stocks
Related parts for IT243
IT243 Summary of contents
Page 1
... Test voltage: Max. partial discharge voltage: Temperature range (operation and storage): Flammability corresponding to: IT pulse transformers are designed to offer you galvanic isolation for transformer coupled gate drives. The IT series provides negligible delays and the possibility of voltage scaling. They are available with single or double secondary winding for multiple gate drives ...
Page 2
... Explanations: – rise time at given load resistor R and 70% of the output pulse height. – primary inductance measured at 1kHz (secondary coile open). – L str stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils only one at the time is connected (measuring frequency 10kHz). ...
Page 3
Components > IT series Dimensions IT 213 IT 243 IT 244 A Ø19 17.6 17.6 B 16.7 16 11.3 11 0.45 0.42 0. 0.4 0 15.3 15.3 H ...
Page 4
... This document has been carefully taiwansales@schaffner.com checked. However, Schaffner does not assume any liability for errors or inac- Thailand curacies. Schaffner EMC Co. Ltd thailandsales@schaffner.com UK Schaffner Ltd. T +44 118 9770070 uksales@schaffner.com USA Schaffner EMC Inc 732 225 9533 Toll free 1 800 367 5566 usasales@schaffner.com ...