ZX-XF12

Manufacturer Part Number
ZX-XF12
Description
ATTACHMNT SIDEVIEW ZX-LT1001/005
Manufacturer
Omron
Datasheets

Specifications of ZX-XF12

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZXXF12
*1. The response speed of the linear output is calculated as the measurement period
*2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
*3. A Calculating Unit (ZX-CAL2) is required. Setting is possible via the monitor focus function.
*4. A Calculating Unit (ZX-CAL2) is required.
Note:
22
Measurement period
Possible average count settings *1 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
Linear output *2
Judgement outputs
(3 outputs: HIGH/PASS/LOW)
Zero reset input, timing input, reset
input, judgement output hold input
Function
Indications
Voltage influence
(including Sensor)
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Connection method
Weight (packed state)
Materials
Accessories
The response speed of the judgement outputs is calculated as the measurement period
Amplifier Units
For operating details, refer to the operation manual (Cat. No. Z166).
ZX Series (ZX-E)
Model
150 s
Current output: 4 to 20 mA/F.S., Max. load resistance: 300
Voltage output: 4 V ( 5 V, 1 to 5 V *3), Output impedance: 100
NPN open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 1.2 V max.
ON:
OFF: Open (leakage current: 0.1 mA max.)
- Measurement value display
- Linearity adjustment (materials selection)
- Display reverse
- Number of display digit changes
- Bottom hold, peak-to-peak hold
- Average hold
- Initial reset
- OFF-delay timer
- Non-measurement setting
- Automatic teaching
- Reset input
- Linear output correction
- K-(A+B) calculation *4
- Sensor disconnection detection
- Key lock
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red),
7-segment sub-digital display (yellow), power ON (green), zero reset (green), enable (green)
0.5% F.S. of linear output value at 20% of power supply voltage
12 to 24 VDC 10%, Ripple (p-p): 10% max.
140 mA max. with power supply voltage of 24 VDC (with Sensor connected)
Operating and storage: 0 to 50 C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 M
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions
300 m/s
Prewired (standard cable length: 2 m)
Approx. 350 g
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Instruction Manual
Short-circuited with 0-V terminal or 1.5 V or
less
Smart Sensors (Inductive Displacement Type)
min. (at 500 DC)
2
, 3 times each in 6 directions (up, down, left, right, forward, backward)
ZX-EDA11
- Present value/set value/output value/resolution display
- Display OFF mode
- Sample hold
- Self-peak hold
- Delay hold
- Linearity initialization
- One-shot timer
- Direct threshold value setting - Position teaching
- Hysteresis width setting
- Judgement output hold input - Monitor focus
- (A-B) calculations *4
- Mutual interference prevention *4
- Zero reset memory
(average count setting + 1).
PNP open-collector outputs, 30 VDC, 50 mA max.
Residual voltage: 2 V max.
ON:
OFF: Open (leakage current: 0.1 mA max.)
(average count setting + 1).
Supply voltage short-circuited or supply volt-
age within 1.5 V
- Scaling
- ECO mode
- Peak hold
- Self-bottom hold
- Zero reset
- ON-delay timer
- Previous value comparison
- Timing inputs
- (A+B) calculations *4
- Zero reset indicator
ZX-EDA41