ZX-XF12 Omron, ZX-XF12 Datasheet - Page 3

no-image

ZX-XF12

Manufacturer Part Number
ZX-XF12
Description
ATTACHMNT SIDEVIEW ZX-LT1001/005
Manufacturer
Omron
Datasheets

Specifications of ZX-XF12

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZXXF12
Specifications
■ Sensor Heads (Reflective)
*1. Beam size: The beam size is defined by 1/e
*2. Resolution: The resolution is the deviation (±3σ) in the linear output when connected to the ZX-LDA Amplifier Unit. (The resolution is measured
*3. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The
*4. Temperature characteristic: The temperature characteristic is measured at the measurement point with the Sensor and reference object
Note: Highly reflective objects can result in incorrect detection by causing out-of-range measurements.
Item
Optical system
Light source (wave
length)
Measurement point
Measurement range
Beam shape
Beam size*1
Resolution*2
Linearity*3
Temperature
characteristic*4
Ambient illumination
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
occur if there is light leakage outside the defined spot and the material around the sensing object is more reflective than the sensing object.
with the standard reference object (white ceramic), at the measurement point with the ZX-LDA set for an average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may
be adversely affected under strong electromagnetic fields.
linearity and measurement values vary with the object being measured.
(OMRON’s standard reference object) secured with an aluminum jig.
Model
Diffuse reflective
Visible-light semiconductor laser with a wavelength of 650 nm and an output of 1 mW max.
EN class 2, FDA class II
40 mm
±10 mm
Spot
50-µm dia.
2 µm
±0.2% FS
(entire
range)
±0.03% FS/°C (Except for ZX-LD300 and ZX-LD300L, which are ±0.1% FS/°C.)
Incandescent lamp: 3,000 l× max. (on light receiving side)
Operating: 0 to 50°C, Storage: −15 to 60°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
300 m/s
IEC60529, IP50
Connector relay (standard cable length: 500 mm)
Approx. 150 g
Case: PBT (polybutylene terephthalate),
Cover: Aluminum, Lens: Glass
Instruction sheet, Laser warning label (English)
ZX-LD40
2
3 times each in six directions (up/down, left/right, forward/backward)
100 mm
±40 mm
100-µm dia.
16 µm
±0.2% FS
(80 to 120
mm)
ZX-LD100
2
(13.5%) of the strength of the beam at the beam center (measured value). Incorrect detection may
300 mm
±200 mm
300-µm dia.
300 µm
±2% FS
(200 to 400
mm)
ZX-LD300
ZX Series (ZX-L-N)
Regular re-
flective
30 mm
±2 mm
75-µm dia.
0.25 µm
±0.2% FS
(entire
range)
IEC60529,
IP40
Approx. 250
g
Case and
cover: Alumi-
num, Lens:
Glass
ZX-LD30V
Diffuse reflective
40 mm
±10 mm
Line
75 µm x 2
mm
2 µm
±0.2% FS
(32 to 48
mm)
IEC60529, IP50
Approx. 150 g
Case: PBT (polybutylene terephthalate),
Cover: Aluminum, Lens: Glass
ZX-LD40L
Smart Sensors (Laser Type)
100 mm
±40 mm
150 µm x 2
mm
16 µm
±0.2% FS
(80 to 120
mm)
ZX-LD100L
300 mm
±200 mm
450 µm x 2
mm
300 µm
±2% FS
(200 to 400
mm)
ZX-LD300L
Regular reflec-
tive
30 mm
±2 mm
100 µm x 1.8
mm
0.25 µm
±0.2% FS
(entire range)
IEC60529,
IP40
Approx. 250 g
Case and cov-
er: Aluminum,
Lens: Glass
Z3X-LD30VL
3

Related parts for ZX-XF12