Z4LC-C28 Omron, Z4LC-C28 Datasheet
Z4LC-C28
Specifications of Z4LC-C28
Related parts for Z4LC-C28
Z4LC-C28 Summary of contents
Page 1
... Ordering Information J SENSOR Sensing distance Measurement width 300 mm J CONTROLLER Controller J EXTENSION CABLE Extension cable for emitter and receiver Type Part number Integrated type Z4LC-S2840 Separate type Z4LC-S28 Type Part number NPN model Z4LC-C28 Cable length Part number 2 m Z49- Z49-C6 8M Z4LC 1 ...
Page 2
... Main functions 2 Z4LC-S28 0 to 300 mm 0.5 mm dia. Emitter: Approx. 250 g Receiver: Approx. 250 g Z4LC-C28 7-segment LED, 4 digits 10 µm 20 µm (process value for averaging: 16 mA, load impedance: 300 Ω max. 3.3 ms (process value for averaging: 1) 12-bit binary output NPN open collector output: 30 VDC max. ...
Page 3
... Output data Measurement data, error messages, setting conditions output Input commands Measurement mode selection, forced zero, etc. Z4LC-C28 Operating 50°C (32_F to 122_F) with no icing or condensation Storage: --15 to 60°C (5_F to 140_F) with no icing or condensation Operating/Storage 85% (with no condensation 150 Hz half-amplitude of 0. acceleration of 20 m/s ...
Page 4
... The range of analog output can be set within the measurement width 28 mm. Enable Mode Measurement Function The processing item (i.e. maximum, minimum, maximum minus minimum, or average) can be set. The set item is calculated and output while the enable mode signal is input. Suitable for the measurement of bar movement. Z4LC ...
Page 5
... Z4LC Nomenclature J SENSORS Z4LC-S2840 Z4LC-S28 (Link has been omitted.) Connector J CONTROLLER Z4LC-C28 Forced zero indicator Display Discrimination indicators Bank No. indicator Operation J INPUT/OUTPUT SPECIFICATIONS I/O Signals I/O Signals Input Signals Enable input (ENABLE) LD OFF input (LD-OFF) Bank switch input (BANK) Forced zero input (ZERO) ...
Page 6
... Z4LC J TERMINAL CONNECTIONS Z4LC-C28 (Rear Section) D-sub connector (communications) 28-pin Connector (I/ VDC 28-pin Connector (I/O) Pin No. Signals 1 Output COM 2 D0 (LSB D10 8 STB 9 PASS 10 ERR 11 ZERO 12 ENABLE 13 Input COM 14 Linear Output GND 15 Output COM D11 (MSB LOW 24 LD-OFF 25 BANK 26 EXRESET 27 Input COM ...
Page 7
... J INPUT/OUTPUT CIRCUIT Input Circuit Input 2.2 kΩ Input 560 Ω Power supply (see note) Input COM ( VDC) Output Circuit Note: There is no need to be con- Photocoupler Output Load Output Load Power supply ( VDC) Output COM Z4LC cerned about the polarity of power supply. 7 ...
Page 8
... Z4LC Dimensions Unit: mm (inch) J CONTROLLER Z4LC-C28 (3.86) 96 (3.78) 48 (1.89) J SENSORS Z4LC-S2840 31 (1.22) 11.5 dia. 15.5±0.3 (0.61±0.012 (3.58) 120 (4.72) 12 (0.47) 130 (5.12) 44 (1.73) Connector Vinyl-insulated round cable, 5 dia. (7/0.18 dia.), 4 conductors Standard length 123 (4.84) 55 (2.17) Optical axis 28 (1.10) 42 ...
Page 9
... Emitter Two, 4.5 dia. Four, M4, depth: 4 Z4LC Optical axis Connector 14.7 dia. Vinyl-insulated round cable, 5.8 dia. (7/0.18 dia.), 7 conductors Standard length (1.10) Beam 35.5 (1.40) Two, Receiver 4.5 dia. Four, M4, depth: 4 ...
Page 10
... The Z4LC Parallel Beam Line Sensor Class 1 Laser Product according to EN60825 (IEC825) and JIS C6802 and a Class II Laser Product according to FDA (21 CFR1040.10) (see note). The Z4LC is meant to be built into final system equipment. Pay special attention to the following precautions for the safe use of the product: Note: Europe: Class 1 of EN60825: 1991 = IEC825: 1984 & ...
Page 11
... NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC MSEN4 4/01 Use an insulated transformer for the power supply of the Z4LC as shown in the illustration. Do not use an autotransformer or the Z4LC may malfunction. Autotransformer Commercial power supply Insulated transformer Commercial ...