GRM022R60J103KE19D Murata Electronics North America, GRM022R60J103KE19D Datasheet - Page 3

CAP CER 10000PF 6.3V X5R 01005

GRM022R60J103KE19D

Manufacturer Part Number
GRM022R60J103KE19D
Description
CAP CER 10000PF 6.3V X5R 01005
Manufacturer
Murata Electronics North America
Series
GRMr

Specifications of GRM022R60J103KE19D

Capacitance
10000pF
Voltage - Rated
6.3V
Tolerance
±10%
Temperature Coefficient
X5R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 85°C
Applications
General Purpose
Package / Case
01005 (0402 Metric)
Size / Dimension
0.016" L x 0.008" W (0.40mm x 0.20mm)
Thickness
0.20mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Ratings
-
Lead Spacing
-
Other names
490-4538-2
!Note
No.
14
15
16
17 Durability
*2: GRM31CR60J107, GRM31CD80G107: 0.15 max.
*3: GRM31CR71E106: 0.125 max.
*4: GRM153R60G105, GRM188R60J106: Within 12.5%
GRM Series Specifications and Test Methods (2)
Continued from the preceding page.
Resistance
to
Soldering
Heat
Temperature
Sudden
Change
High
Temperature
High
Humidity
(Steady)
1. This Specifications and Test Methods is downloaded from the website of Murata Manufacturing co.,ltd. Therefore, it's specifications are subject to change or our products in it may be discontinued without advance notice.
0.
2. This Specifications and Test Methods has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product
0.
Please check with our sales representatives or product engineers before ordering.
specifications before ordering.
Item
Appearance
Capacitance
Change
D.F.
I.R.
Dielectric
Strength
Appearance
Capacitance
Change
D.F.
I.R.
Dielectric
Strength
Appearance
Capacitance
Change
D.F.
I.R.
Appearance
Capacitance
Change
D.F.
I.R.
No defects or abnormalities
B1, B3, R1, R6*
F1, F5: Within 20%
B1, B3, R1, R6*
C6: 0.125 max.
F1, F5: 0.2 max.
More than 50 · F
No defects
No defects or abnormalities
B1, B3, R1, R6, R7, C6, C7, C8, D7, D8: Within 7.5%
E7: Within 30%
F1, F5: Within 20%
B1, B3, R1, R6*
C6: 0.125 max.
F1, F5: 0.2 max.
More than 50 · F
No defects
No defects or abnormalities
B1, B3, R1, R6, R7, C6, C7, C8, E7, D7, D8: Within 12.5%
F1, F5: Within 30%
B1, B3, R1, R6, R7, C6, C7, C8, E7, D7, D8: 0.2 max.
F1, F5: 0.4 max.
More than 12.5 · F
No defects or abnormalities
B1, B3, R1, R6, R7, C6, C7, C8, E7, D7, D8: Within 12.5%
F1, F5: Within 30%
B1, B3, R1, R6, R7, C6, C7, C8, E7, D7, D8: 0.2 max.
F1, F5: 0.4 max.
More than 25 · F
4
2
2
, R7, C6, C7, C8, E7, D7, D8: Within 7.5%
, R7*
, R7*
3
3
, C7, C8, E7, D7, D8*
, C7, C8, E7, D7, D8*
Specifications
2
2
: 0.1 max.
: 0.1 max.
Preheat the capacitor at 120 to 150 C for 1 minute.
Immerse the capacitor in an eutectic solder or Sn-3.0Ag-0.5Cu
solder solution at 270 5 C for 10 0.5 seconds. Set at room
temperature for 24 2 hours, then measure.
*Do not apply to GRM02.
•Initial measurement for high dielectric constant type
Perform a heat treatment at 150+0/–10 C for one hour and
then set at room temperature for 24 2 hours.
Perform the initial measurement.
*Preheating for GRM32/43/55
Fix the capacitor to the supporting jig in the same manner and
under the same conditions as (10).
Perform the five cycles according to the four heat treatments
shown in the following table.
Set for 24 2 hours at room temperature, then measure.
•Initial measurement for high dielectric constant type
Perform a heat treatment at 150+0/–10 C for one hour and
then set at room temperature for 24 2 hours.
Perform the initial measurement.
Apply the rated voltage at 40 2 C and 90 to 95% humidity for
500 12 hours. The charge/discharge current is less than 50mA.
•Initial measurement
Perform a heat treatment at 150+0/–10 C for one hour and
then let sit for 24 2 hours at room temperature. Perform the
initial measurement.
•Measurement after test
Perform a heat treatment at 150+0/–10 C for one hour and
then let sit for 24 2 hours at room temperature, then measure.
Apply 150% of the rated voltage for 1000 12 hours at the
maximum operating temperature 3 C. Let sit for 24 2 hours at
room temperature, then measure.
The charge/discharge current is less than 50mA.
•Initial measurement
Perform a heat treatment at 150+0/–10 C for one hour and
then let sit for 24 2 hours at room temperature. Perform the
initial measurement.
•Measurement after test
Perform a heat treatment at 150+0/–10 C for one hour and
then let sit for 24 2 hours at room temperature, then measure.
Time (min.)
Temp. ( C)
Step
Step
1
2
Temp. +0/–3
Operating
30 3
Min.
Temperature
100 to 120 C
170 to 200 C
1
Test Method
Temp.
Room
2 to 3
2
Temp. +3/–0
Operating
Max.
30 3
3
1 min.
1 min.
Time
Temp.
Room
2 to 3
4

Related parts for GRM022R60J103KE19D