C0402C153K9PACTU Kemet, C0402C153K9PACTU Datasheet
C0402C153K9PACTU
Specifications of C0402C153K9PACTU
C0402C153K9PAC
C0402C153K9PAC7867
Related parts for C0402C153K9PACTU
C0402C153K9PACTU Summary of contents
Page 1
... Additional reeling or packaging options may be available. Contact KEMET for details. 2 One WORLD © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com in capacitance with respect to time and voltage and boasts a minimal change in capacitance with reference to ambient temperature. Capacitance change is limited to ± ...
Page 2
... Note: When measuring capacitance it is important to ensure the set voltage level is held constant. The HP4284 & Agilent E4980 have a feature known as Automatic Level Control (ALC). The ALC feature should be switched to "ON". © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com W ...
Page 3
... KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Capacitance Value DF (%) 3.0 All 7.5 < 0.56µF 7.5 ≥ 0.56µF 12.0 Dissipation Factor (Limit) ...
Page 4
... K M Voltage DC Cap Cap Voltage Code Code Series C1005 C0201 UD = Under Development, xx¹ Available only in K,M tolerance, xx² Available only in M tolerance. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com C0402 C0603 ...
Page 5
... Thickness Chip Thickness ± Code Size Range (mm) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com QTY per Reel QTY per Reel QTY per Reel 7" Plastic 13" Plastic 4000 10000 ...
Page 6
... Density Level C: For high component density product applications. Before adapting the minimum land pattern variations the user should perform qualification testing based on the conditions outlined in IPC standard 7351 (IPC-7351). © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com QTY per Reel QTY per Reel 7" ...
Page 7
... For optimized solderability, chip stock should be used promptly, preferably within 1.5 years of receipt. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Test or Inspection Method Appendix 1, Note: Force of 1.8kg for 60 seconds. ...
Page 8
... Figure 1 for W and P carrier tape reference locations. 1 *Refer to Table 6 for tolerance specifi cations. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Bar Code Label Anti-Static Reel Embossed Plastic* or Punched Paper Carrier. Sprocket Holes ...
Page 9
... B are measured on a plane 0.3mm above the bottom of the pocket (f) see Addendum in EIA Document 481 for standards relating to more precise taping requirements. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com P 2 [10 pitches cumulative Po tolerance on tape ± ...
Page 10
... Figure 4). e) see Addendum in EIA Document 481 for standards relating to more precise taping requirements. 2. The tape with or without components shall pass around R without damage (see Figure 5). © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com P 2 ...
Page 11
... Tape 0.5 mm maximum 0.5 mm maximum Figure 5 – Bending Radius Embossed Punched Carrier Carrier Bending R R Radius © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Peel Strength Maximum Component Rotation Maximum ° ° s Rotation ( ) ...
Page 12
... Tape Size N Min 8mm 12mm (1.969) 16mm © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Access Hole at Slot Location (Ø min.) C (Arbor hole diameter) If present, tape slot in core for tape start: 2 ...
Page 13
... Figure 8 – Maximum Camber Elongated sprocket holes (32 mm & wider tapes maximum, either direction Straight Edge 250 mm © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Carrier Tape Round Sprocket Holes START 100 mm Min. Leader ...
Page 14
... Table 10 – Capacitor Marking Laser marking is available as an extra-cost option for most KEMET ceramic chips. Such marking is two sided, and includes identify KEMET, followed by two characters (per EIA-198) to identify the capacitance value. Note that marking is not available for any Y5V chip. ln addition, the 0603 marking option is limited to the K only. (Marking Optional – ...
Page 15
... Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Tools http://capacitoredge ...
Page 16
... Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © ...