C1210Y103K2RACTU Kemet, C1210Y103K2RACTU Datasheet - Page 8

CAP CER 10000PF 200V X7R 1210

C1210Y103K2RACTU

Manufacturer Part Number
C1210Y103K2RACTU
Description
CAP CER 10000PF 200V X7R 1210
Manufacturer
Kemet
Series
FF-CAPr

Specifications of C1210Y103K2RACTU

Capacitance
10000pF
Voltage - Rated
200V
Tolerance
±10%
Temperature Coefficient
X7R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 125°C
Features
Floating Electrode, Soft Termination
Applications
Automotive, Boardflex Sensitive
Ratings
AEC-Q200
Package / Case
1210 (3225 Metric)
Size / Dimension
0.138" L x 0.102" W (3.50mm x 2.60mm)
Thickness
0.78mm
Capacitor Application
General Purpose
Dielectric Characteristic
X7R
Capacitance Tolerance
± 10%
Voltage Rating
200V
Capacitor Case Style
1210
Capacitor Mounting
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Spacing
-
Other names
C1210Y103K2RAC
C1210Y103K2RAC7800
SMD MLCCs – Floating Electrode Design with Flexible Termination System (FF-CAP), X7R Dielectric, (Commercial & Automotive Grade)
Table 4 – Performance & Reliability: Test Methods and Conditions
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Resistance to Solvents
High Temperature Life
Temperature Cycling
Moisture Resistance
Mechanical Shock
Terminal Strength
Biased Humidity
Thermal Shock
Ripple Current
Solderability
Storage Life
Board Flex
Stress
MIL-STD-202 Method 103
MIL-STD-202 Method 106
MIL-STD-202 Method 107
MIL-STD-202 Method 108
MIL-STD-202 Method 108
MIL-STD-202 Method 213
MIL-STD-202 Method 215
JESD22 Method JA-104
Heat Generation
∆T : 20ºC max.
Reference
JIS-C-6429
JIS-C-6429
J-STD-002
Reflow solder the capacitor onto a PC board and apply voltage with 10kHz~1Mhz sine curve.
(Ripple voltage must be < rated voltage)
Appendix 1, Note: Force of 1.8kg for 60 seconds.
Appendix 2, Note: 2mm (min) for all except 3mm for C0G.
Magnification 50X. Conditions:
1000 Cycles (-55°C to +125°C), Measurement at 24 hrs. +/- 2 hrs after test conclusion.
Load Humidity: 1000 hours 85°C/85%RH and Rated Voltage.Add 100K ohm resistor. Measurement
at 24 hrs. +/- 2 hrs after test conclusion.
Low Volt Humidity: 1000 hours 85C°/85%RH and 1.5V.Add 100K ohm resistor.
Measurement at 24 hrs. +/- 2 hrs after test conclusion.
t = 24 hours/cycle. Steps 7a & 7b not required. Unpowered.
Measurement at 24 hrs. +/- 2 hrs after test conclusion.
-55°C/+125°C. Note: Number of cycles required-300, Maximum transfer time-20 seconds, Dwell
time-15 minutes. Air-Air.
1000 hours at 125°C (85°C for X5R, Z5U and Y5V) with 1.5X rated voltage applied.
150°C, 0VDC, for 1000 Hours.
Figure 1 of Method 213, Condition F.
Add aqueous wash chemical - OKEM Clean or equivalent.
a) Method B, 4 hrs @ 155°C, dry heat @ 235°C
b) Method B @ 215°C category 3
c) Method D, category 3 @ 260°C
Test or Inspection Method
C1015-1 • 9/14/2010
8

Related parts for C1210Y103K2RACTU